zl30100 Zarlink Semiconductor, zl30100 Datasheet - Page 14

no-image

zl30100

Manufacturer Part Number
zl30100
Description
T1/e1 System Synchronizer
Manufacturer
Zarlink Semiconductor
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
zl30100QD
Manufacturer:
ZARILNK
Quantity:
20 000
Part Number:
zl30100QDC
Manufacturer:
MAXIM
Quantity:
4
Part Number:
zl30100QDC1
Manufacturer:
ZARLINK
Quantity:
101
Part Number:
zl30100QDG1
Manufacturer:
ZARLINK
Quantity:
20 000
Examples:
HMS=1: When 10 Normal to Holdover to Normal mode transitions occur and in each case the Holdover mode was
entered for 2 seconds, then the accumulated phase change (MTIE) could be as large as 3.13 Ps.
where:
REF
Output
Clock
-
-
-
-
-
REF
Output
Clock
REF
Output
Clock
REF
Output
Clock
Phase
Phase
Phase
0.15 ppm is the accuracy of the Holdover mode
0 ns is the maximum phase discontinuity in the transition from the Normal mode to the Holdover mode
holdover_drift
mode_change
10 changes
= 10 x (300 ns + 13 ns) = 3.13 Ps
TIE_CLR=0
Normal mode
Phase drift in Holdover mode
Return to Normal mode
= 0.15 ppm x 2 s = 300 ns
= 0 ns + 13 ns = 13 ns
HMS = 0
Figure 8 - Timing Diagram of Hitless Mode Switching
Zarlink Semiconductor Inc.
ZL30100
14
REF
Output
Clock
REF
Output
Clock
REF
Output
Clock
REF
Output
Clock
TIE_CLR=0
Normal mode
Phase drift in Holdover mode
Return to Normal mode
HMS = 1