hs1b-11r IDEC Corporation, hs1b-11r Datasheet
hs1b-11r
Related parts for hs1b-11r
hs1b-11r Summary of contents
Page 1
... HS9Z-P1 Conduit Opening Plug *Torx is a registered trademark of Camcar Textron. GS-ET-15 BG standard in Germany Direct Opening Action Part Numbers Pilot Light Part Number Without HS1B-11R With red LED HS1B-114R-R With green LED HS1B-114R-G Without HS1B-02R With red LED HS1B-024R-R With green LED HS1B-024R-G ...
Page 2
... HS1B Series Specifi cations Conforming to Standards IEC60947-5-1, EN60947-5-1, GS-ET-15, UL508 Operating Temperature –25 to +70˚C (no freezing) Storage Temperature –40 to +80˚C Operating Humidity 85% RH maximum (no condensation) Altitude 2,000m maximum Rated Insulation Voltage (Ui) 300V (between LED and ground: 60V) Impulse Withstand Voltage (Uimp (between LED and ground: 2.5 kV) Between live and dead metal parts: 100 MΩ ...
Page 3
... Main Circuit: used to enable the machine to start only when the main circuit is closed. Auxiliary Circuit: used to indicate whether the main circuit or door is open or closed. 2. Terminals + and - are used for the LED indicator, and are isolated from door status. Wire the terminals only when needed. USA: 800-262-IDEC Canada: 888-317-IDEC HS1B Series Status ...
Page 4
... Actuator Angle Adjustment • Using the screw (M3 hex socket head screw), the actuator angle can be adjusted (refer to the dimensional drawing). Adjustable angle: (0˚) to 20˚ 364 Dimensions (mm) HS1B - using the Right-angle actuator (HS9Z-A2) (Horizontal Mounting) Conduit Port G1/2 Actuator Actuator Cover Slot Plug ...
Page 5
Door Interlock Switches • In order to avoid electric shock or a fi re, turn the power off before installation, removal, wire connection, maintenance, or inspection of the switch. • If relays are used in the circuit between the safety ...
Page 6
... The safety switch cover can be only removed with the special key wrench supplied with the switch or with the optional screwdriver (also applicable to HS1B and HS1E). • Remove the screw located on the unlocking entry at the side of the switch us- ing the key wrench included with the switch. Then insert a small screwdriver into the switch to push the lever inside of the switch toward the indicator until the actuator is unlocked (refer to the diagram on the right) ...
Page 7
... HS1C: 5.0±0.5 N-m (approx. 50±5 kgf-cm pcs of M5 hex socket head cap screws) ø4.1 min. • HS1B: 5.0±0.5 N-m (approx. 50±5 kgf-cm pcs hex socket head cap screws) Crimping Terminal 2 • HS2B: 5.0±0.5 N-m (approx. 50±5 kgf-cm) (2 pcs of M5 hex socket head cap screws) • ...
Page 8
Precautions Actuator Angle Adjustment • Using the screw (M3 hex socket head screw), the actuator angle can be adjusted (refer to the dimensional drawing). Adjustable angle: (0˚) to 20˚ • The larger the adjusted angle of the actuator, the smaller ...