362
Specifi cations
Conforming to Standards
Operating Temperature
Storage Temperature
Operating Humidity
Altitude
Rated Insulation Voltage (Ui)
Impulse Withstand Voltage (Uimp)
Insulation Resistance
Electric Shock Protection Class
Pollution Degree
Degree of Protection
Vibration
Resistance
Shock Resistance
Actuator Operating Speed
Positive Opening Travel
Positive Opening Force
Thermal Current (Ith)
Rated Operating Current (Ie)
Operating Frequency
Mechanical Life
Electrical Life
Conditional Short-circuit Current
Recommended Short Circuit Protection
Indicator
Weight
Operating Extremes
Damage Limits
Operating Voltage
Current
Light Source
Lens Color
HS1B Series
IEC60947-5-1, EN60947-5-1, GS-ET-15, UL508
–25 to +70˚C (no freezing)
–40 to +80˚C
85% RH maximum (no condensation)
2,000m maximum
300V (between LED and ground: 60V)
4 kV (between LED and ground: 2.5 kV)
Between live and dead metal parts: 100 MΩ minimum
Between live metal part and ground: 100 MΩ minimum
Between live metal parts:
Between terminals of the same pole: 100 MΩ minimum
Class I (IEC61140)
3 (IEC60947-5-1)
IP67 (IEC60529)
10 to 55 Hz, amplitude 0.5mm p-p
60 m/sec
1,000 m/sec
1 m/sec maximum
11 mm minimum
20N minimum
10A
Operating Voltage (Ue)
900 operations/hour
1,000,000 operations
100,000 operations (rated load)
100A (IEC60947-5-1)
250V, 10A fuse (Type D01 based on IEC60269-1, 60269-2)
24V DC
10 mA
LED lamp
Red or Green (12 mm dia. Lens)
Approx. 280g
AC
DC
2
Resistive load (AC12)
Inductive load (AC15)
Resistive load (DC12)
Inductive load (DC13)
(approx. 6G)
2
(approx. 100G)
www.idec.com
10A
10A
100 MΩ minimum
30V
8A
4A
125V
2.2A
1.1A
10A
5A
250V
1.1A
0.6A
6A
3A
Door Interlock Switches