LS4301-7R POWER-ONE [Power-One], LS4301-7R Datasheet
LS4301-7R
Related parts for LS4301-7R
LS4301-7R Summary of contents
Page 1
Cassette Style 100 Watt AC-DC Converters with PFC Input voltage range from 85...264 isolated outputs I/O electric strength test voltage • Universal input voltage range • Power ...
Page 2
Cassette Style Type Survey and Key Data Non standard input/output configuration or special custom adaptions are available on request. See also: Commercial Infor- mation: Inquiry Form for Customized Power Supply. Table 1: Type survey LS Output 1 Output 2 U ...
Page 3
Cassette Style Functional Description The input voltage is fed via an input fuse, an input filter, a rectifier and an inrush current limiter to a single transistor boost converter. This converter provides a sinusoidal input current (IEC/EN 61000-3-2, class D ...
Page 4
Cassette Style Electrical Input Data General Conditions – unless T is specified – Pin 18 connected to pin 14, U adjusted – Sense line pins S+ and S– connected to Vo+ ...
Page 5
Cassette Style Input Inrush Current Characteristic I [A] inr 130 100 Fig. 4 Theoretical input inrush current versus time at U and 115 rms ext Harmonic Currents The harmonic distortion is ...
Page 6
Cassette Style Electrical Output Data General Conditions – unless T is specified – Pin 18 (i) connected to pin 14 (S–/Vo1–), U – Sense line pins 12 (S+) and 14 (S–) connected to pins ...
Page 7
Cassette Style Table 4b: Output data double output modules Output (Outputs connected in Series) Characteristics Conditions 2 U Output voltage nom U Overvoltage protection op (supressor diode Output current U o nom i min T ...
Page 8
Cassette Style Table 4c: Output data double output modules Output 1 (Outputs independently loaded) Characteristics Conditions U Output voltage nom U Overvoltage protection op (supressor diode Output current U o nom i min T C ...
Page 9
Cassette Style Thermal Considerations If a converter is located in free, quasi-stationary air (con- vection cooling) at the indicated maximum ambient tem- perature T (see table: Temperature specifications) and A max is operated at its nominal input voltage and output ...
Page 10
Cassette Style [ 12.5 12.0 11.5 11 10.5 0 0.2 0.4 0.6 Fig 5320 (typ.) vs. I with different [ 16.5 16 15.5 15 14.5 14 13.5 0 ...
Page 11
Cassette Style Auxiliary Functions i Inhibit for Remote On and Off Note: With open i input: Output is disabled ( U The outputs of the module may be enabled or disabled by means of a logic signal (TTL, CMOS, etc.) ...
Page 12
Cassette Style Programmable Output Voltage (R-Function standard feature, the modules offer an adjustable out- put voltage, identified by letter R in the type designation. The control input R (pin 16) accepts either a control voltage ...
Page 13
Cassette Style R-Function for different output configurations Vo2+ 4 Vo2 Vo2– Vo2– Vo1+ 12 Vo1– ext ext R 16 Fig. 21a LS 5000 with H15 ...
Page 14
Cassette Style Display Status of LEDs U > 0.95...0. adj min U > 0.95...0. adj nom i ...
Page 15
Cassette Style Electromagnetic Compatibility (EMC) A metal oxide VDR together with an input fuse and an input filter form an effective protection against high input tran- sient voltages which typically occur in most installations. The S series has been successfully ...
Page 16
Cassette Style Electromagnetic Emission [ Fig. 23 Typical disturbance voltage (quasi-peak) at the input accord- ing to CISPR 11/22 and EN 55011/22, measured at U and ...
Page 17
Cassette Style Immunity to Environmental Conditions Table 9: Environment specifications Test method Standard Ca Damp heat IEC/DIN IEC 60068-2-3 steady state MIL-STD-810D section 507.2 Ea Shock IEC/EN/DIN EN 60068-2-27 (half-sinusoidal) MIL-STD-810D section 516.3 Eb Bump IEC/EN/DIN EN 60068-2-29 (half-sinusoidal) MIL-STD-810D ...
Page 18
Cassette Style Mechanical Data Dimensions in mm. Tolerances 0.3 mm unless otherwise indicated. 171.93 (DIN 41494 152 152 Front plate Main face 0.5 168.5 Fig. 25 Aluminium case S02 with heatsink, black finish and self cooling, weight: Approx. ...
Page 19
Cassette Style Safety and Installation Instructions Connector Pin Allocation The connector pin allocation table defines the electrical potentials and the physical pin positions on the H15 con- nector. Pin no. 24, the protective earth pin present on all LS AC-DC ...
Page 20
Cassette Style Standards and Approvals All AC-DC converters correspond to class I equipment. They are UL recognized according to UL 1950, UL recog- nized for Canada to CAN/CSA C22.2 No. 950-95 and LGA approved to IEC/EN 60950 standards. The units ...
Page 21
Cassette Style Table 14: Leakage currents Characteristic Maximum earth Permissible according to IEC/EN 60950 leakage current Specified value at 254 Safety of operator accessible output circuit If the output circuit of an AC-DC converter is operator ac- ...
Page 22
Cassette Style E Inrush Current Limitation The converters may be supplemented by an electronic cir- cuit (option E, replacing the standard built-in NTC) to achieve an enhanced inrush current limiting function. Table 17: Inrush current characteristics with option E Characteristics ...
Page 23
Cassette Style D Undervoltage Monitor The input and/or output undervoltage monitoring circuit op- erates independently of the built-in input undervoltage lock- out circuit. A logic "low" (JFET output) or "high" signal (NPN output) is generated at pin 20 as soon ...
Page 24
Cassette Style D-signal with respect to input and output voltage versus time: Input voltage monitoring NPN high low high I D low 0 JFET ...
Page 25
Cassette Style V ACFAIL Signal (VME) Available for units with U = 5.1V o1 This option defines an undervoltage monitoring circuit for the input or input and main output voltage equivalent to op- tion D and generates the ACFAIL signal ...
Page 26
Cassette Style Input voltage monitoring high U V low high U V low 5.1 V 4.875 V 2 ...
Page 27