74AHC04D,118 NXP Semiconductors, 74AHC04D,118 Datasheet - Page 4

IC HEX INVERTER 14SOIC

74AHC04D,118

Manufacturer Part Number
74AHC04D,118
Description
IC HEX INVERTER 14SOIC
Manufacturer
NXP Semiconductors
Series
74AHCr
Datasheet

Specifications of 74AHC04D,118

Number Of Circuits
6
Logic Type
Inverter
Package / Case
14-SOIC (3.9mm Width), 14-SOL
Number Of Inputs
1
Current - Output High, Low
8mA, 8mA
Voltage - Supply
2 V ~ 5.5 V
Operating Temperature
-40°C ~ 125°C
Mounting Type
Surface Mount
Logic Family
AHC
High Level Output Current
- 8 mA
Low Level Output Current
8 mA
Supply Voltage (max)
5.5 V
Supply Voltage (min)
2 V
Maximum Operating Temperature
+ 125 C
Mounting Style
SMD/SMT
Operating Supply Voltage
5 V
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant
Other names
74AHC04D-T
74AHC04D-T
935263040118

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
74AHC04D,118
Manufacturer:
NEXPERIA/安世
Quantity:
20 000
NXP Semiconductors
7. Limiting values
Table 4.
In accordance with the Absolute Maximum Rating System (IEC 60134). Voltages are referenced to GND (ground = 0 V).
[1]
[2]
8. Recommended operating conditions
Table 5.
74AHC_AHCT04
Product data sheet
Symbol
V
V
I
I
I
I
I
T
P
Symbol Parameter
74AHC04
V
V
V
T
Δt/ΔV
74AHCT04
V
V
V
T
Δt/ΔV
IK
OK
O
CC
GND
stg
amb
amb
CC
I
tot
CC
I
O
CC
I
O
The input and output voltage ratings may be exceeded if the input and output current ratings are observed.
For SO14 packages: above 70 °C the value of P
For TSSOP14 packages: above 60 °C the value of P
For DHVQFN14 packages: above 60 °C the value of P
supply voltage
input voltage
output voltage
ambient temperature
input transition rise and fall rate
supply voltage
input voltage
output voltage
ambient temperature
input transition rise and fall rate
Parameter
supply voltage
input voltage
input clamping current
output clamping current
output current
supply current
ground current
storage temperature
total power dissipation
Limiting values
Operating conditions
All information provided in this document is subject to legal disclaimers.
V
V
T
Conditions
V
amb
I
O
O
Conditions
V
V
V
< −0.5 V
< −0.5 V or V
= −0.5 V to (V
CC
CC
CC
tot
= −40 °C to +125 °C
derates linearly at 8 mW/K.
= 3.0 V to 3.6 V
= 4.5 V to 5.5 V
= 4.5 V to 5.5 V
tot
Rev. 5 — 11 April 2011
tot
derates linearly at 5.5 mW/K.
derates linearly at 4.5 mW/K.
O
CC
> V
+ 0.5 V)
CC
+ 0.5 V
74AHC04; 74AHCT04
Min
2.0
0
0
−40
-
-
4.5
0
0
−40
-
[1]
[1]
[2]
Min
−0.5
−0.5
−20
−20
−25
-
−75
−65
-
Typ
-
-
+25
-
-
-
-
+25
-
5.0
5.0
Max
+7.0
+7.0
-
+20
+25
+75
-
+150
500
Max
5.5
5.5
V
+125
100
20
5.5
5.5
V
+125
20
CC
CC
© NXP B.V. 2011. All rights reserved.
hex inverter
Unit
V
V
mA
mA
mA
mA
°C
Unit
V
V
°C
ns/V
V
V
°C
ns/V
mA
mW
V
ns/V
V
4 of 15