ax88190 ASIX Electronics Corporation, ax88190 Datasheet - Page 20

no-image

ax88190

Manufacturer Part Number
ax88190
Description
Pcmcia 10/100m Fast Ethernet Mac Controller
Manufacturer
ASIX Electronics Corporation
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
ax88190AL
Manufacturer:
TOSHIBA
Quantity:
1 001
Part Number:
ax88190AL
Manufacturer:
ASLX
Quantity:
1 000
Part Number:
ax88190AL
Manufacturer:
ASLX
Quantity:
20 000
Part Number:
ax88190P
Manufacturer:
ASIX
Quantity:
1 122
Part Number:
ax88190P
Manufacturer:
ASIX
Quantity:
20 000
4.3.1 Command Register (CR) Offset 00H (Read/Write)
4.3.2 Interrupt Status Register (ISR) Offset 07H (Read/Write)
FIELD
FIELD
7:6
5:3
2
1
0
7
6
5
4
3
2
1
0
AX88190
RD2,RD1
PS1,PS0 PS1,PS0 : Page Select
START START :
NAME
NAME
STOP
OVW
,RD0
RDC
CNT
TXE
RXE
PRX
TXP
RST
PTX
The two bit selects which register page is to be accessed.
RD2,RD1,RD0 : Remote DMA Command
These three encoded bits control operation of the Remote DMA channel. RD2 could be set
to abort any Remote DMA command in process. RD2 is reset by AX88190 when a Remote
DMA has been completed. The Remote Byte Count should be cleared when a Remote DMA
has been aborted. The Remote Start Address are not restored to the starting address if the
Remote DMA is aborted.
TXP : Transmit Packet
This bit could be set to initiate transmission of a packet
This bit is used to active AX88190 operation.
STOP : Stop AX88190
This bit is used to stop the AX88190 operation.
Reset Status :
CR. Writing to this bit is no effect.
Remote DMA Complete
Counter Overflow
OVERWRITE : Set when receive buffer ring storage resources have been exhausted.
Transmit Error
Receive Error
Packet Transmitted
Packet Received
RD2 RD1 RD0
Set when AX88190 enters reset state and cleared when a start command is issued to the
Set when remote DMA operation has been completed
Set when MSB of one or more of the Tally Counters has been set.
Set when packet transmitted with one or more of the following errors
Indicates that a packet was received with one or more of the following errors
Indicates packet received with no error.
Indicates packet transmitted with no error
0
0
0
0
1
PS1
n Excessive collisions
n
CRC error
Frame Alignment Error
FIFO Overrun
Missed Packet
0
0
FIFO Under-run
0
1
0
0
1
1
X
PS0
X
0
1
0
1
PCMCIA Fast Ethernet MAC Controller
page 0
page 1
Not allowed
Remote Read
Remote Write
Not allowed
Abort / Complete Remote DMA
20
DESCRIPTION
DESCRIPTION
ASIX ELECTRONICS CORPORATION

Related parts for ax88190