AT89C51RC
A 50% duty cycle clock can be programmed to come out on P1.0, as shown in Figure 6.
This pin, besides being a regular I/O pin, has two alternate functions. It can be pro-
grammed to input the external clock for Timer/Counter 2 or to output a 50% duty cycle
clock ranging from 61 Hz to 4 MHz at a 16 MHz operating frequency.
To configure the Timer/Counter 2 as a clock generator, bit C/T2 (T2CON.1) must be
cleared and bit T2OE (T2MOD.1) must be set. Bit TR2 (T2CON.2) starts and stops the
timer.
The clock-out frequency depends on the oscillator frequency and the reload value of
Timer 2 capture registers (RCAP2H, RCAP2L), as shown in the following equation.
In the clock-out mode, Timer 2 roll-overs will not generate an interrupt. This behavior is
similar to when Timer 2 is used as a baud-rate generator. It is possible to use Timer 2 as
a baud-rate generator and a clock generator simultaneously. Note, however, that the
baud-rate and clock-out frequencies cannot be determined independently from one
another since they both use RCAP2H and RCAP2L.
The AT89C51RC has a total of six interrupt vectors: two external interrupts (INT0 and
INT1), three timer interrupts (Timers 0, 1, and 2), and the serial port interrupt. These
interrupts are all shown in Figure 7.
Each of these interrupt sources can be individually enabled or disabled by setting or
clearing a bit in Special Function Register IE. IE also contains a global disable bit, EA,
which disables all interrupts at once.
Note that Table 5 shows that bit position IE.6 is unimplemented. User software should
not write 1s to these bit positions, since they may be used in future AT89 products.
Timer 2 interrupt is generated by the logical OR of bits TF2 and EXF2 in register
T2CON. Neither of these flags is cleared by hardware when the service routine is vec-
tored to. In fact, the service routine may have to determine whether it was TF2 or EXF2
that generated the interrupt, and that bit will have to be cleared in software.
The Timer 0 and Timer 1 flags, TF0 and TF1, are set at S5P2 of the cycle in which the
timers overflow. The values are then polled by the circuitry in the next cycle. However,
the Timer 2 flag, TF2, is set at S2P2 and is polled in the same cycle in which the timer
overflows.
Clock-Out Frequency
=
------------------------------------------------------------------------------------ -
4 x [65536-(RCAP2H,RCAP2L)]
Oscillator Frequency
1920B–MICRO–11/02