Q2406B

Manufacturer Part NumberQ2406B
ManufacturerWAVECOM
Q2406B datasheet
 


Specifications of Q2406B

Date_code06+  
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
Page 61
62
Page 62
63
Page 63
64
Page 64
65
Page 65
66
Page 66
67
Page 67
68
Page 68
69
Page 69
70
Page 70
71
72
73
74
75
76
77
78
79
80
81
Page 64/81

Download datasheet (903Kb)Embed
PrevNext
6 Appendix
6.1 Wavecom acceptance test
These tests are Wavecom internal qualification tests. They are performed on a
Wavecom evaluation platform (module on test board).
Applied standard
Test
Performance
Mobile Station (MS) conformance
Test
specification; Part 1:
Conformance
(Release 5).
3GPP TS 51.010 v5.0.0 (2002-09)
Cooking Test
-
Stress Test
Therma shocks IEC 68-2-14.
Vibration Test
Sinusoidal vibration IEC 68-2-6.
Vibration Test
Random vibration IEC 68-2-36.
Shock Test
IEC 68-2-27.
Bump Test
IEC 68-2-29.
Humidity Test
Corrosion test IEC 68-2-3.
Warehouse
Low temperance IEC 68-2-1.
Test
Warehouse
High temperature IEC 68-2-2.
Test
Dust Test1
MIL-STD-810D, method 510-3.
Light Test1
UV radiation and temperature EDF
HN60E03.
Fall Test1
IEC 68-2-32.
confidential ©
This document is the sole and exclusive property of WAVECOM. Not to be distributed or divulged
without prior written agreement.
Ce document est la propriété exclusive de WAVECOM. Il ne peut être communiqué ou divulgué à
des tiers sans son autorisation préalable.
WM_PRJ_Q2400_PTS_002 - 002
Full conformity to the recommendation regarding
the main RF parameters.
specification
The test continues even after the Cooking Test
milestone has been reached
Full conformity to the recommendation regarding
the main parameters.
No
performance
degradation is allowed after test.
No
performance
degradation is allowed after test.
No
performance
degradation is allowed after test.
No
performance
degradation is allowed after test.
No visible degradation of the product, both
visual and functionnal.
The unit is tested at room temperature and must
be fully operative for the main RF parameters.
Under normal condition (room temperature) after
the test, the unit must behave in full conformity
with the main RF parameters specification.
Under normal condition (room temperature) after
the test, the unit must behave in full conformity
with the main RF parameters specification.
No visible dust in the visible areas. No more than
50 dust particules in the cabinet of the product.
The unit, tested at room temperature must be
fully operative.
Visual inspection on the discoloration and other
degradation
effects
material of the unit after the test.
Only minor casing degradation is allowed, with a
maximum dimension change of 1mm. The unit
must remain fully operative and full specification
for the main RF parameters.
24th January 2003
Acceptance criteria
degradation
or
mechanical
degradation
or
mechanical
degradation
or
mechanical
degradation
or
mechanical
such
as
cracks
in
Page : 64 / 81
the