Specifications of WIZ1000-US

Rohs
yes
Product
Serial to Ethernet Servers
Interface Type
RS-232
Operating Supply Voltage
5 V
Maximum Operating Temperature
+ 70 C
Dimensions
75 mm x 45 mm
Minimum Operating Temperature
0 C
WIZ1000 User’s Manual
(Version1.0)
©2009 WIZnet Co., Ltd. All Rights Reserved.
☞ For more information, visit our website at
http://www.wiznet.co.kr

Related parts for WIZ1000-US

WIZ1000-US Summary of contents

Page 1

... WIZ1000 User’s Manual (Version1.0) ©2009 WIZnet Co., Ltd. All Rights Reserved. ☞ For more information, visit our website at http://www.wiznet.co.kr ...

Page 2

... If you want to know more about WIZnet products, please visit WIZnet website (www.wiznet.co.kr), and you could also put your questions on Q&A Board. Our engineers will reply you as soon as possible Copyright © WIZnet All Rights Reserved WIZ1000 | 2 page ...

Page 3

... Document Revision History Date Revision 2009-06-26 V1.0 Copyright Notice Copyright 2009 WIZnet, Inc. All Rights Reserved. Technical Support: support@wiznet.co.kr Sales & Distribution: sales@wiznet.co.kr For more information, please visit our website: Copyright © WIZnet All Rights Reserved Changes First Release http://www.wiznet.co.kr WIZ1000 | 3 page ...

Page 4

... Trade Name or Applicant : WIZnet, Inc. - Equipment Name : Serial to Ethernet Device Server - Basic Model Number : WIZ1000 - Manufacturer / Country of Origin : WIZnet, Inc. / KOREA - Certification Number : WWW-WIZ1000-S2E(A) This equipment has been tested for a Class A digital device. ...

Page 5

... OMMAND ORMAT 4.2. WIZ1000 C ONFIGURATION WITH 5. TELNET COM PORT OPTIONS ....................................................................... 30 6. DEMONSTRATION AND TEST ........................................................................ 34 6. ARDWARE NTERFACE 6. ESTING ERIAL TO THERNET 7. WIZ1000 HARDWARE SPECIFICATION ............................................................. 36 7.1. P ......................................................................................... 36 ARAMETERS 7.2. S ....................................................................................... 36 PECIFICATION 7. OARD IMENSIONS AND 8. WARRANTY ............................................................................................. 38 Copyright © WIZnet All Rights Reserved Table of Contents ................................................................................ 9 ............................................................................... 11 ...

Page 6

... Table 5. Serial Configuration STX & ETX .................................................... 25 Table 6. Serial Configuration Reply Code .................................................... 25 Table 7. Serial Configuration Command Code .............................................. 27 Table 8. Serial Configuration Testing Process ............................................... 29 Table 9 Telnet Com Port Options List ......................................................... 32 Table 10. Testing Environment of WIZ1000 .................................................. 34 Table 11. RS-232 PIN Assignment ............................................................ 37 Copyright © WIZnet All Rights Reserved FIGURES Tables ...

Page 7

... Introduction WIZ1000 is one model of Serial to Ethernet Device Server which is one finished product of WIZnet with CE, FCC and KCC certifications. WIZ1000 acts as a gateway between RS-232 and Ethernet. It enables remote gauging, managing and control of a device through the network based on Ethernet and TCP/IP by connecting to the existing equipment with RS-232 serial interface ...

Page 8

... Specification The specifications of WIZ1000 are introduced in Table 1. ITEM MCU TCP/IP Protocol Network Interface Serial Interface Serial Signal Serial Parameters Input Voltage Power Consumption Temperature Humidity Copyright © WIZnet All Rights Reserved Description 8051 compliant (having internal 62K Flash, 16K SRAM, 2K EEPROM) W5100 (Ethernet MAC & ...

Page 9

... If there is any missing item, contact to the shop where you purchased. ☞ The optional items should be purchased separately. Copyright © WIZnet All Rights Reserved WIZ1000 Device Server CD (Optional / including Configuration Tool Program, Firmware and Manual) LAN Cable (Optional) 5V Power Adaptor (Optional) Table 2. Products Contents WIZ1000 | 9 page ...

Page 10

... Block Diagram WIZ1000 is a protocol converter that transmits the data sent by serial equipment to Ethernet and converts back the TCP/IP data received through the network into serial data to transmit back to the equipment. When the data is received from serial port sent to W5100 by MCU ...

Page 11

... Figure 2. User Interface of Configuration Tool (Configuration via Network) ⓐ Version : Displays firmware version. The current version of the firmware of selected WIZ1000 is displayed in this field. ⓑ Enable Serial Debug Mode : If this mode is checked, you can monitor the status and socket message of WIZ1000 (listen OK, connect fail etc.) through serial terminal. If Debug mode is on, debug message can cause abnormal operation of the serial device ...

Page 12

... IP Configuration Method: Select IP setting mode, you can select one from Static, DHCP, PPPoE mode. Static: “Static” is the option for setting WIZ1000 with static IP address. First select MAC address that you want to set it as static IP in ‘board list’. Then, the “Local IP, Subnet, Gateway boxes are enabled. Input Static IP address and click “ ...

Page 13

... PPPoE ID/Password : If you select ‘PPPoE’ mode, input ID/Password which you received from ISP company. ⓘ Server IP/Port : When WIZ1000 is set as “Client mode” or Mixed mode”, server IP and port should be set. WIZ1000 attempts to connect this IP address. ⓙ Network mode : client/server/mixed : This is to select the communication method based on TCP ...

Page 14

... TCP Server mode can be useful when the monitoring center tries to connect to the device (where WIZ1000 is installed) in order to check the status or provide the commands. In normal time WIZ1000 is on the waiting status, and if there is any connection request (SYN) from the monitoring center, the connection is established (ESTABLISH), and data communication is processed (Data Transaction) ...

Page 15

... DNS(Domain Name System) is the database system having information about IP address and corresponding domain name. When connecting to domain name, you can use DNS function of WIZ1000. Input IP address of DNS server provided by ISP in DNS Server IP, and domain name in the Server (Domain) If server has dynamic IP address, but domain name, if you use DNS function, you do not need to configure server IP address whenever it’ ...

Page 16

... This function is used for searching the connected WIZ1000s in the same sub-network. If you want to configure or update the firmware of your WIZ1000, you have to find your WIZ1000 at first. In order to protect WIZ1000 from attacking, a search password is needed to input in the popup dialog after “Search” button clicked as shown in Figure 7. The password can be modified by using this configuration tool and its maximum length is 8 bytes ...

Page 17

... To check configuration result, click ‘Search’ button. ⓟ Upload Firmware will be uploaded through network ☞ After uploading the firmware, 20~30 seconds are required for initialization. ⓠ Exit : Close the configuration tool program. Copyright © WIZnet All Rights Reserved values (re-booting is processed) WIZ1000 | 17 page ...

Page 18

... Figure 8. Configuration Tool (Serial Config.) ⓡ COM Port Configuration The parameters of COM port of WIZ1000 are listed well in this page. Users can set the COM port of WIZ1000 by selecting the value of each parameter in the drop down list. ☞ By clicking the “Setting” button, selected value can be applied. ...

Page 19

... Any one of three conditions is satisfied, the data is transmitted to the Ethernet. Ex) Delimiter: Size=10, Char=0x0D Serial data: 0123456789abc Ethernet data: 0123456789 ☞ “abc” will be remained in the serial buffer of module. Copyright © WIZnet All Rights Reserved WIZ1000 | 19 page ...

Page 20

... In order to close the connection, the ‘Close’ command should be given. This function can be used for more than two or more systems to connect to a WIZ1000 module. If one system holds the connection to the WIZ1000, other systems cannot connect to the module ...

Page 21

... Keep-alive packet is usually used to check whether the other side is alive or not. Users can define the interval of sending keep-alive packet here, and timer will be started when there is no data to delivery between WIZ1000 and the other side. The interval can be set between 0~65535 seconds, and 0 means the keep-alive timer is disabled that no keep-alive packet will be sent. ...

Page 22

... Telnet Com Port Option The port of telnet and login password can also be defined by users. The maximum length of telnet login password is 8 bytes and its default password is ‘wiznet’. The default telnet port is 23. Copyright © WIZnet All Rights Reserved WIZ1000 | 22 page ...

Page 23

... Select a module shown in “Board list”, and click “Upload” button. ③ ☞ Before uploading through Ethernet, you should set the network information of WIZ1000 first by Configuration Tool program as shown above Fig 10. By using Ping test, Copyright © WIZnet All Rights Reserved Figure 11. Board Search Window ...

Page 24

... When the window as shown below Figure is displayed, select file for upload and click ④ “Open” button. Figure 12. Open dialog box for uploading ☞ Do not upload any other files except for WIZ1000 application firmware file. The firmware uploading status will be pop up as shown in Figure 13. ⑤ Figure 13. Firmware uploading window ⑥ ...

Page 25

... Serial Configuration 4.1. Serial Command Format It is possible to configure WIZ1000 by using serial command. By inputting specified 3 characters you can enter into the configuration mode. The characters can be defined at the Configuration Tool. <Frame Format> Command Frame format Descriptor STX Length(bytes) Table 3. Serial Configuration Frame Format ...

Page 26

... Set server port number Restart DNS IP Setting Domain Setting PPPoE ID Setting PPPoE Password Setting Set delimiter character in hex Set delimiter size Set delimiter time Set Inactivity timer value Get MAC Address Check DNS Use or Not DNS IP Check Domain Check WIZ1000 | 26 page ...

Page 27

... Get the serial baud rate Get the serial command method Get the command mode character Get the firmware version Get the server IP address Get the server port number Get delimiter character in hex Get delimiter size Get delimiter time Get Inactivity timer value WIZ1000 | 27 page ...

Page 28

... WIZ1000 Configuration with Serial Command ① Check WIZ1000 Firmware version. If version is lower, download the latest firmware from download page of http://www.wiznet.co.kr Figure13. Serial Configuration Enable Setting At the default status, the serial configuration is disabled. So, click ‘enable’ check box of ② serial configuration and click ‘setting’ button. The defaut value of string is “+++”. ...

Page 29

... Figure 15 Serial Configuration Console Display Copyright © WIZnet All Rights Reserved Enter Serial Configuration mode Successfully entered Change the IP address to 192.168.11.3 Sucessfully change the IP address Check IP address of the module Check changed IP address Re-boot Successfully re-booted Table 8. Serial Configuration Testing Process WIZ1000 | 29 page ...

Page 30

... Telnet Com Port Option is also supported in WIZ1000 for configuration of Com Port remotely. The Telnet Com Port Option of WIZ1000 is compatible with RFC2217. A RFC2217 compliant Telnet client program can also be used to access WIZ1000. We also provide a Telnet Com Port Option client program and its user interface is shown in Figure 16. ...

Page 31

... The Com port configuration procedure can be started only if the “DO” reply is received from WIZ1000. For each command, the value used to query the current settings of WIZ1000. After any setting, the “Over!” button should be clicked to tell WIZ1000 that the configuration is over ...

Page 32

... Set CTS signal state OFF Refer to RFC2217 Refer to RFC2217 Refer to RFC2217 Table 9 Telnet Com Port Options List Supported? Yes Yes Yes No No Yes Yes Yes Yes Yes Yes No No Yes Yes No No Yes Yes Yes Yes No Yes Yes Yes No Yes Yes Yes WIZ1000 | 32 page ...

Page 33

... WIZ1000 to reboot it and apply the new value. WIZ1000 only replies the “WILL” and request command Com port option value is received by WIZ1000, it will not reply this command but setting. Moreover, any RFC2217 compliant Telnet tool can be used to communicate with WIZ1000 ...

Page 34

... Demonstration and Test In this chapter, we give an example that can be used to test the function of WIZ1000 The testing environment is as below. 1) RS232 Port 2) LAN Port Hardware 1) Configuration Tool Program Software 2) Hyper Terminal Table 10. Testing Environment of WIZ1000 6.1. Hardware Interface Serial Cable Install as below steps. ...

Page 35

... STEP 2: Connect the WIZ1000 to the serial device by using serial cable. STEP 3: Connect 5V DC adaptor for power supplying. 6.2. Testing Serial to Ethernet Function STEP1: Power on WIZ1000 board. STEP2: Configure the WIZ1000 by using Configuration Tool program. STEP3: Execute terminal emulator program such as Hyper Terminal, and select the COM port that WIZ1000 will use ...

Page 36

... Specification MCU 8051 Compliant FLASH 62KByte (MCU Internal) SRAM 16KByte (MCU Internal) EEPROM 2KByte (MCU Internal) 7.3. Board Dimensions and Pin Assignment 7.3.1. Dimensions 5.2 H Copyright © WIZnet All Rights Reserved 6.3 I 22.5 J 11.5 9.0 K 8.0 L 22.5 Figure 20. WIZ1000 Dimension 5.0 M 87.5 N 4.5 9.0 O 25.0 P 11.5 WIZ1000 | 36 page ...

Page 37

... Figure 21. RJ-45 PIN Assignment Description Hardware Trigger signal Input Receive Data Transmit Data External Power Ground (Internally shorted to GND) Ground Not connect Request To Send Clear To Send External Power Input (5V) Table 11. RS-232 PIN Assignment Signal TX+ TX- RX+ RX- 5 WIZ1000 | 37 page ...

Page 38

... WIZnet warrants our products and its parts against defects in materials and workmanship under normal use for period of standard ONE(1) YEAR for the WIZ1000 board and labor warranty after the date of original retail purchase. During this period, WIZnet will repair or replace a defective products or part free of charge ...