DS2437S-3/T&R Maxim Integrated Products, DS2437S-3/T&R Datasheet
DS2437S-3/T&R
Specifications of DS2437S-3/T&R
Related parts for DS2437S-3/T&R
DS2437S-3/T&R Summary of contents
Page 1
... DS2437. This means that battery packs need only have three output connectors: battery power, ground, and the 1-Wire interface. Because each DS2437 contains a unique silicon serial number, multiple DS2437s can exist on the same 1-Wire bus. This allows multiple battery packs to be charged or used in the system simultaneously. ...
Page 2
Applications for the smart battery pack monitor include portable computers, portable/cellular telephones, and handheld instrumentation battery packs in which it is critical to monitor real-time battery performance. Used in conjunction with a microcontroller in the battery pack or host system, ...
Page 3
Control function commands may be issued which instruct the DS2437 to perform a temperature measurement or battery voltage A/D conversion. The result of these measurements will be placed in the DS2437’s memory map, and may be read by issuing a ...
Page 4
OPERATION – MEASURING TEMPERATURE The DS2437 measures temperatures through the use of an onboard proprietary temperature measurement technique. The temperature reading is provided in a 13-bit, two’s complement reading, which provides 0.03125°C of resolution. Table 1 describes the exact relationship ...
Page 5
Voltage is expressed in this register in scaled binary format, as outlined in Table 2. Note that while codes exist for values below 2.7V, accuracy of the ADC and the limitation on the DS2437’s supply voltage make it unlikely that ...
Page 6
The current is measured by the ADC with a signed 10-bit (0.004883C) resolution, and the last completed measurement is placed in the CURRENT REGISTER in a sign-extended 2’s-complement format. This register is scaled such that a count of 205 current ...
Page 7
The ICA is a scaled 8-bit (0.01C resolution) volatile binary counter which represents the amount of capacity remaining in the battery in terms of the full capacity (1C), normalized to a count of 100 an ICA count of 100 represents ...
Page 8
The CCA/DCA will accumulate charging/discharging current, and the counter information will be shadowed to EEPROM each time the respective counter increments by 0.32C. The memory location is reserved for the CCA/DCA, and the entire page SHOULD NOT be written ...
Page 9
OPERATION – REAL TIME CLOCK The 32.768 kHz crystal oscillator is used as the time base for the timekeeping functions. The timekeeping functions are double-buffered, allowing the master to read time without the data changing while it is being read. ...
Page 10
LASERED ROM Each DS2437 contains a unique ROM code that is 64 bits long. The first 8 bits are a 1-Wire family code (DS2437 code is 1Eh). The next 48 bits are a unique serial number. The last 8 ...
Page 11
CRC CODE Figure 4 ROM FUNCTIONS FLOWCHART Figure DS2437 ...
Page 12
MEMORY/CONTROL FUNCTIONS FLOWCHART Figure DS2437 YES ...
Page 13
MEMORY/CONTROL FUNCTIONS FLOWCHART Figure 6 Cont'd DS2437 RECALLS EEPROM PAGE INTO SP PAGE DS2437 X X ...
Page 14
MEMORY MAP The DS2437’s memory is organized as shown in Figure 7. The memory consists of a scratchpad RAM and storage SRAM/EEPROM. The scratchpad helps insure data integrity when communicating over the 1-Wire bus. Data is first written to the ...
Page 15
ADB = A/D Converter Busy Flag A/D conversion in progress on battery voltage conversion complete measurement being made. An A/D conversion takes approximately 10 ms Don’t care Bytes 1 and 2 of ...
Page 16
DS2437 MEMORY MAP Figure 7 1-Wire BUS SYSTEM The 1-Wire bus is a system which has a single bus master and one or more slaves. The DS2437 behaves as a slave. The discussion of this bus system is broken down ...
Page 17
The idle state for the 1-Wire bus is high. If for any reason a transaction needs to be suspended, the bus MUST be left in the idle state if the transaction is to resume. Infinite recovery time can occur between ...
Page 18
Search ROM [F0h] When a system is initially brought up, the bus master might not know the number of devices on the 1-Wire bus or their 64-bit ROM codes. The search ROM command allows the bus master to use a ...
Page 19
The bus master writes a 0-bit. This deselects ROM1 leaving ROM4 as the only device still connected. 9. The bus master reads the remainder of the ROM bits for ROM4 and continues to access the part if desired. This ...
Page 20
Copy Scratchpad [48hxxh] This command copies the scratchpad page xxh into the EEPROM / SRAM memory page xxh of the DS2437. After issuing this command, the user must write a page number to direct which page of memory the scratchpad ...
Page 21
INSTRUCTION DESCRIPTION Initiates temperature Convert T conversion Initiates voltage A/D Convert V conversion NOTES: 1. Temperature conversion takes second. 2. A/D conversion takes ms. 3. EEPROM write takes ms. Sample Command ...
Page 22
Sample Command Sequence Table 8 Example: Bus Master issues a temperature and voltage conversion, then reads the temperature, battery voltage, battery current, all on a single DS2437. MASTER MODE DATA (LSB FIRST Presence Presence ...
Page 23
Sample Command Sequence Table 9 Example: Assuming a single DS2437 is configured for its current accumulators to function, this sequence allows the Bus Master to read the three current accumulators. MASTER MODE DATA (LSB FIRST Presence TX TX ...
Page 24
I/O SIGNALING The DS2437 requires strict protocols to insure data integrity. The protocol consists of several types of signaling on one line: reset pulse, presence pulse, write 0, write 1, read 0, and read 1. All of these signals, with ...
Page 25
Read Time Slots The host generates read time slots when data read from the DS2437. A read time slot is initiated when the host pulls the data line from a logic high level to logic low level. ...
Page 26
READ / WRITE TIMING DIAGRAM Figure DS2437 ...
Page 27
DETAILED MASTER READ 1 TIMING Figure 11 RECOMMENDED MASTER READ 1 TIMING Figure DS2437 ...
Page 28
ABSOLUTE MAXIMUM RATINGS* Voltage on VDD and VAD, Relative to Ground Voltage on VSENS+, VSENS-, Relative to Ground Voltage on Any Pin Relative to Ground Operating Temperature Storage Temperature Soldering Temperature * This is a stress rating only and functional ...
Page 29
ELECTRICAL CHARACTERISTICS: VOLTAGE A/D CONVERTER PARAMETER SYMBOL A/D Error VAD V Input Range Input Range Input Range V DD Resolution Conversion Time t CONVV No Missing Code Temperature Range Monotonicity ELECTRICAL CHARACTERISTICS: CURRENT A/D ...
Page 30
AC ELECTRICAL CHARACTERISTICS: 1-WIRE INTERFACE PARAMETER SYMBOL Time Slot t Recovery Time t Write 0 Low Time t LOW0 Write 1 Low Time t LOW1 Read Data Valid t Reset Time High t RSTH Reset Time Low t Presence Detect ...
Page 31
TIMING DIAGRAMS Figure 14 1-WIRE WRITE 1 TIME SLOT 1-WIRE WRITE 0 TIME SLOT 1-WIRE READ TIME SLOT 1-WIRE RESET PULSE 1-WIRE PRESENCE DETECT DS2437 ...