LM96080CIMTX/NOPB National Semiconductor, LM96080CIMTX/NOPB Datasheet - Page 24

IC HARDWARE MONITOR 24-TSSOP

LM96080CIMTX/NOPB

Manufacturer Part Number
LM96080CIMTX/NOPB
Description
IC HARDWARE MONITOR 24-TSSOP
Manufacturer
National Semiconductor
Series
PowerWise®r
Datasheet

Specifications of LM96080CIMTX/NOPB

Function
Hardware Monitor
Topology
ADC (Sigma Delta), Comparator, Fan Speed Counter, Register Bank
Sensor Type
External & Internal
Sensing Temperature
-40°C ~ 125°C, External Sensor
Output Type
I²C™
Output Alarm
No
Output Fan
Yes
Voltage - Supply
3 V ~ 5.5 V
Operating Temperature
-40°C ~ 125°C
Mounting Type
Surface Mount
Package / Case
24-TSSOP
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
LM96080CIMTX

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
LM96080CIMTX/NOPB
Manufacturer:
NS/TI
Quantity:
19
Part Number:
LM96080CIMTX/NOPB
Manufacturer:
TI
Quantity:
8 000
Part Number:
LM96080CIMTX/NOPB
0
Company:
Part Number:
LM96080CIMTX/NOPB
Quantity:
6 000
www.national.com
Bit
0
1
2
3
4
5
6
7
12.7 Interrupt Mask Register 2—Address 04h
Power on default <7:0> = 0000 0000 binary
Hot Temperature
BTI
FAN1
FAN2
GPI (Chassis
Intrusion)
OS bit
Hot Temperature
Interrupt Mode
Select
OS Bit Interrupt
Mode Select
Name
Read/Write
Read/Write A one disables the corresponding interrupt status bit for INT interrupt.
Read/Write A one disables the corresponding interrupt status bit for INT interrupt.
Read/Write A one disables the corresponding interrupt status bit for INT interrupt.
Read/Write A one disables the corresponding interrupt status bit for INT interrupt.
Read/Write A one disables the corresponding interrupt status bit for INT interrupt.
Read/Write A one disables the corresponding interrupt status bit for INT interrupt.
Read/Write A zero selects the default interrupt mode which gives the user an interrupt if the temperature
Read/Write A zero selects the default interrupt mode which gives the user an interrupt if the temperature
goes above the hot limit. The interrupt will be cleared once the status register is read, but it will
again be generated when the next conversion has completed. It will continue to do so until the
temperature goes below the hysteresis limit.
A one selects the one time interrupt mode which only gives the user one interrupt when it goes
above the hot limit. The interrupt will be cleared once the status register is read. Another in-
terrupt will not be generated until the temperature goes below the hysteresis limit. It will also
be cleared if the status register is read. No more interrupts will be generated until the temper-
ature goes above the hot limit again. The corresponding bit will be cleared in the status register
every time it is read but may not set again when the next conversion is done. (Refer to the
Temperature Interrupt Response Diagram in Section 8.2).
goes above the OS limit. The interrupt will be cleared once the status register is read, but it will
again be generated when the next conversion has completed. It will continue to do so until the
temperature goes below the hysteresis limit.
A one selects the one time interrupt mode which only gives the user one interrupt when it goes
above the OS limit. The interrupt will be cleared once the status register is read. Another in-
terrupt will not be generated until the temperature goes below the hysteresis limit. It will also
be cleared if the status register is read. No more interrupts will be generated until the temper-
ature goes above the OS limit again. The corresponding bit will be cleared in the status register
every time it is read but may not set again when the next conversion is done. (Refer to the
Temperature Interrupt Response Diagram in Section 8.2).