Specifications of LM84CIMQA

Function
Hardware Monitor
Topology
ADC (Sigma Delta), Comparator, Register Bank
Sensor Type
External & Internal
Sensing Temperature
0°C ~ 125°C, External Sensor
Output Type
SMBus™
Output Alarm
Yes
Output Fan
No
Voltage - Supply
3 V ~ 3.6 V
Operating Temperature
0°C ~ 125°C
Mounting Type
Surface Mount
Package / Case
16-SSOP
For Use With
LM84EVAL - EVALUATION BOARD FOR LM84
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Other names
*LM84CIMQA

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
LM84CIMQA
Manufacturer:
NS
Quantity:
2
Part Number:
LM84CIMQA
Manufacturer:
SMD
Quantity:
1
Part Number:
LM84CIMQA
Manufacturer:
NS/国半
Quantity:
20 000
Part Number:
LM84CIMQAX
Manufacturer:
NEC
Quantity:
56
Logic Electrical Characteristics
1.0 Functional Description
The LM84 temperature sensor incorporates a band-gap type
temperature sensor using a Local or Remote diode and an
8-bit ADC (Delta-Sigma Analog-to-Digital Converter). The
LM84 is compatible with the serial SMBus and I
faces. Digital comparators compare Local and Remote read-
ings to user-programmable setpoints (LT_CRIT and
RT_CRIT). Activation of the T_CRIT_A output indicates that
a temperature reading is greater than the limit preset in a
T_CRIT register.
1.1 T_CRIT_A OUTPUT, T_CRIT LIMITS
T_CRIT_A is activated when the Local temperature reading
is greater than the limit preset in the local critical temperature
setpoint register (LT_CRIT) or when the Remote tempera-
ture reading is greater than the limit preset in the remote
critical temperature setpoint register (RT_CRIT), as shown in
Figure 3 . The T_CRIT_A mask bit (bit 7 of the Configuration
Register) when set will disable the T_CRIT_A output.
The Status Register can be read to determine which event
caused the alarm. A bit in the Status Register is set high to
indicate T_CRIT temperature alarm, see Section 1.8.3 .
Local and remote temperature diodes are sampled alter-
nately by the A/D converter. The T_CRIT_A output and the
Status Register flags are updated at the completion of a
conversion, which takes approximately 60 ms. T_CRIT_A
and the Status Register flags are reset only after the Status
Register is read and if the temperature is below the setpoint.
FIGURE 2. Temperature-to-Digital Transfer Function (Non-linear scale for clarity)
2
C inter-
(Continued)
9
1.2 POWER-ON RESET DEFAULT STATES
LM84 always powers up to these known default states:
1. Local Temperature set to 0˚C
2. Remote Temperature set to 0˚C until the LM84 senses a
3. Status Register set to 00h.
4. Command Register set to 00h; T_CRIT_A enabled.
5. Local and Remote T_CRIT set to 127˚C
FIGURE 3. T_CRIT_A Temperature Response Diagram
diode present or open circuit on the D+ and D− input
pins.
DS100961-5