HCPL-2200-000E Avago Technologies US Inc., HCPL-2200-000E Datasheet - Page 6

OPTOCOUPLER LOGIC 2.5MBD 8-DIP

HCPL-2200-000E

Manufacturer Part Number
HCPL-2200-000E
Description
OPTOCOUPLER LOGIC 2.5MBD 8-DIP
Manufacturer
Avago Technologies US Inc.
Datasheet

Specifications of HCPL-2200-000E

Package / Case
8-DIP (0.300", 7.62mm)
Voltage - Isolation
3750Vrms
Number Of Channels
1, Unidirectional
Current - Output / Channel
25mA
Data Rate
2.5MBd
Propagation Delay High - Low @ If
210ns @ 3mA
Current - Dc Forward (if)
10mA
Input Type
DC
Output Type
Tri-State
Mounting Type
Through Hole
Isolation Voltage
3750 Vrms
Maximum Continuous Output Current
25 mA
Maximum Fall Time
0.007 us
Maximum Forward Diode Current
10 mA
Output Device
Logic Gate Photo IC
Configuration
1 Channel
Maximum Baud Rate
5 MBd(Typ)
Maximum Forward Diode Voltage
1.7 V
Maximum Reverse Diode Voltage
5 V
Maximum Power Dissipation
210 mW
Maximum Operating Temperature
+ 85 C
Minimum Operating Temperature
- 40 C
No. Of Channels
1
Optocoupler Output Type
Logic Gate
Input Current
5mA
Output Voltage
20V
Opto Case Style
DIP
No. Of Pins
8
Common Mode Ratio
2.5k
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant
Other names
516-1647-5

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
HCPL-2200-000E
Manufacturer:
AVAGO
Quantity:
5 000
Part Number:
HCPL-2200-000E
Manufacturer:
AVAGO/安华高
Quantity:
20 000
6
IEC/EN/DIN EN 60747-5-2 Insulation Related Characteristics (HCPL-2219 OPTION 060 ONLY)
*Refer to the front of the optocoupler section of the current catalog, under Product Safety Regulations section, IEC/EN/DIN EN 60747-5-2, for a
detailed description.
Note: Isolation characteristics are guaranteed only within the safety maximum ratings which must be ensured by protective circuits in application.
Description
Installation classification per DIN VDE 0110/1.89, Table 1
Climatic Classification
Pollution Degree (DIN VDE 0110/1.89)
Maximum Working Insulation Voltage
Input to Output Test Voltage, Method b*
Input to Output Test Voltage, Method a*
Highest Allowable Overvoltage*
(Transient Overvoltage, t
Safety Limiting Values
Insulation Resistance at T
for rated mains voltage 300 V rms
for rated mains voltage 450 V rms
V
Partial Discharge < 5 pC
V
t
(Maximum values allowed in the event of a failure,
also see Figure 12, Thermal Derating curve.)
m
IORM
IORM
Case Temperature
Input Current
Output Power
= 60 sec, Partial Discharge < 5 pC
x 1.875 = V
x 1.5 = V
PR
, Type and sample test,
PR
, 100% Production Test with t
ini
S
, V
= 10 sec)
IO
= 500 V
m
= 1 sec,
P
Symbol
I
S,OUTPUT
S,INPUT
V
V
V
V
IORM
IOTM
R
T
PR
PR
S
S
Characteristic
55/85/21
1181
6000
I-IV
I-III
630
945
175
230
600
10
2
9
V
Units
V
V
V
mW
mA
peak
peak
peak
peak
C

Related parts for HCPL-2200-000E