Specifications of HCPL-263N

Voltage - Isolation
3750Vrms
Number Of Channels
2, Unidirectional
Current - Output / Channel
50mA
Data Rate
10MBd
Propagation Delay High - Low @ If
53ns @ 3.5mA
Current - Dc Forward (if)
10mA
Input Type
DC
Output Type
Open Collector
Mounting Type
Through Hole
Package / Case
8-DIP (0.300", 7.62mm)
No. Of Channels
2
Isolation Voltage
3.75kV
Optocoupler Output Type
Logic Gate
Input Current
10mA
Output Voltage
7V
Opto Case Style
DIP
No. Of Pins
8
Propagation Delay Low-high
100ns
Common Mode Voltage Vcm
1000V
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Other names
516-1096-5

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
HCPL-263N
Manufacturer:
AVAGO
Quantity:
8 000
Part Number:
HCPL-263N-000E
Manufacturer:
AVAGO
Quantity:
3 100
Part Number:
HCPL-263N-000E
Manufacturer:
AVAGO
Quantity:
8 000
Part Number:
HCPL-263N-020E
Manufacturer:
AVAGO
Quantity:
20 000
Part Number:
HCPL-263N-300E
Manufacturer:
AVAGO
Quantity:
8 000
Part Number:
HCPL-263N-520E
Manufacturer:
AVAGO/安华高
Quantity:
20 000
Insulation and Safety Related Specifications
Option 300 – surface mount classification is Class A in accordance with CECC 00802.
IEC/EN/DIN EN 60747-5-2 Insulation Related Characteristics
Description
Installation classification per DIN VDE 0110/1.89, Table 1
Climatic Classification
Pollution Degree (DIN VDE 0110/1.89)
Maximum Working Insulation Voltage
Input to Output Test Voltage, Method b*
Input to Output Test Voltage, Method a*
Highest Allowable Overvoltage*
(Transient Overvoltage, t
Safety Limiting Values
(See below for Thermal Derating Curve Figures)
Insulation Resistance at T
*Refer to the front of the optocoupler section of the current catalog, under Product Safety Regulations section IEC/EN/DIN EN 60747-5-2, for a
detailed description.
Note: Isolation characteristics are guaranteed only within the safety maximum ratings which must be ensured by protective circuits in application.
6
Parameter
Minimum External Air
Gap (External
Clearance)
Minimum External
Tracking (External
Creepage)
Minimum Internal Plastic
Gap (Internal Clearance)
Tracking Resistance
(Comparative Tracking
Index)
Isolation Group
for rated mains voltage ≤ 150 V rms
for rated mains voltage ≤ 300 V rms
for rated mains voltage ≤ 600 V rms
V
with t
V
t
Case Temperature
Input Current
Output Power
m
IORM
IORM
= 60 sec, Partial Discharge < 5 pC
x 1.875 = V
x 1.5 = V
m
= 1 sec, Partial Discharge < 5 pC
PR
, Type and Sample Test,
PR
, 100% Production Test
ini
S
, V
= 10 sec)
IO
= 500 V
Symbol
L(101)
L(102)
CTI
8-Pin DIP
(300 Mil)
Value
0.08
200
7.1
7.4
IIIa
Value
SO-8
0.08
200
Symbol
V
V
V
V
T
I
P
R
4.9
4.8
IIIa
S,INPUT
S
S,OUTPUT
S
IORM
PR
PR
IOTM
Units
Volts
mm
mm
mm
PDIP Option 060
I-IV
I-III
55/85/21
2
630
1181
945
6000
175
230
600
≥ 10
Conditions
Measured from input terminals to
output terminals, shortest distance
through air.
Measured from input terminals to
output terminals, shortest distance
path along body.
Through insulation distance, conductor
to conductor, usually the direct
distance between the photoemitter and
photodetector inside the optocoupler
cavity.
DIN IEC 112/ VDE 0303 Part 1
Material Group (DIN VDE 0110, 1/89,
Table 1)
9
SO-8 Option 60
I-IV
I-III
I-II
55/85/21
2
566
1063
849
4000
150
150
600
≥ 10
9
Units
V
V
V
V
˚C
mA
mW
peak
peak
peak
peak