JC100A1 Lineage Power, JC100A1 Datasheet

no-image

JC100A1

Manufacturer Part Number
JC100A1
Description
CONVERTER DC/DC 5V 100W OUT
Manufacturer
Lineage Power
Series
JC100r
Type
Isolated with Remote On/Offr
Datasheet

Specifications of JC100A1

Output
5V
Number Of Outputs
1
Power (watts)
100W
Mounting Type
Through Hole
Voltage - Input
18 ~ 36V
Package / Case
9-DIP Module
1st Output
5 VDC @ 20A
Size / Dimension
2.40" L x 2.28" W x 0.50" H (61mm x 57.9mm x 12.7mm)
Power (watts) - Rated
100W
Operating Temperature
-40°C ~ 100°C
Efficiency
85%
Approvals
CSA, UL, VDE
Product
Isolated
Output Power
100 W
Input Voltage Range
18 V to 36 V
Input Voltage (nominal)
28 V
Output Voltage (channel 1)
5 V
Output Current (channel 1)
20 A
Isolation Voltage
1.5 KV
Package / Case Size
DIP
Output Type
Isolated
Output Voltage
5 V
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
3rd Output
-
2nd Output
-
4th Output
-
Lead Free Status / Rohs Status
No

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
JC100A1
Manufacturer:
LUCENT
Quantity:
27
Part Number:
JC100A1
Manufacturer:
IR
Quantity:
452
Part Number:
JC100A1
Manufacturer:
LUCENT
Quantity:
20 000
Part Number:
JC100A1
Quantity:
55
Data Sheet
March 2008
Description
The JC050A, JC075A, JC100A Power Modules are dc-dc converters that operate over an input voltage range of
18 Vdc to 36 Vdc and provide a precisely regulated dc output. The outputs are fully isolated from the inputs, allow-
ing versatile polarity configurations and grounding connections. The modules have maximum power ratings from
50 W to 100 W at typical full-load efficiency of 85%.
The sealed modules offer metal baseplate for excellent thermal performance. Threaded-through holes are pro-
vided to allow easy mounting or addition of a heat sink for high-temperature applications. The standard feature set
includes remote sensing, output trim, and remote on/off for convenient flexibility in distributed power applications.
surface-mount technology and deliver high-quality, efficient,
compact dc-dc conversion.
Applications
n
n
n
n
Options
n
n
The JC050A, JC075A, JC100A Power Modules use advanced,
Distributed power architectures
Workstations
EDP equipment
Telecommunications
Choice of remote on/off logic configuration
Heat sink available for extended operation
JC050A, JC075A, JC100A Power Modules: dc-dc Converters;
18 Vdc to 36 Vdc Input, 5 Vdc Output; 50 W to 100 W
Features
n
n
n
n
n
n
n
n
n
n
n
n
n
n
* UL is a registered trademark of Underwriters Laboratories, Inc.
† CSA is a registered trademark of Canadian Standards Assn.
Small size: 61.0 mm x 57.9 mm x 12.7 mm
(2.40 in. x 2.28 in. x 0.50 in.)
High power density
High efficiency: 85% typical
Low output noise
Constant frequency
Industry-standard pinout
Metal baseplate
2:1 input voltage range
Overtemperature protection (100 W only)
Remote sense
Remote on/off
Adjustable output voltage
Case ground pin
UL
*
Recognized, CSA
Certified, VDE Licensed

Related parts for JC100A1

JC100A1 Summary of contents

Page 1

Data Sheet March 2008 JC050A, JC075A, JC100A Power Modules: dc-dc Converters; 18 Vdc to 36 Vdc Input, 5 Vdc Output 100 W The JC050A, JC075A, JC100A Power Modules use advanced, surface-mount technology and deliver high-quality, efficient, compact ...

Page 2

... Symbol Min Typ — — I, max I — — I, max I — — I, max — — — — 5 — — 60 March 2008 Max Unit 50 Vdc 1500 Vdc 100 °C 125 °C Max Unit 36 Vdc 3.5 A 5 — mAp-p — dB Lineage Power ...

Page 3

... O Load Change from I = 50 Peak Deviation Settling Time (V < 10% of peak deviation) O Table 3. Isolation Specifications Parameter Isolation Capacitance Isolation Resistance Lineage Power 18 Vdc to 36 Vdc Input, 5 Vdc Output 100 W (continued) Device Symbol All V O, set All V All — All — ...

Page 4

... O, clamp Tc March 2008 Typ Max Unit 2,600,000 hr. — 100 (3.5) g (oz.) Min Typ Max Unit 0 — 1.2 V — — 1.0 mA — — — — 50 µA — — — 0 — 110 %V O, nom 5.9 — 7.0 V — 105 — °C Lineage Power ...

Page 5

... INPUT VOLTAGE, V Figure 1. Typical JC050A Input Characteristics at Room Temperature INPUT VOLTAGE, V Figure 2. Typical JC075A Input Characteristics at Room Temperature Lineage Power 18 Vdc to 36 Vdc Input, 5 Vdc Output 100 (A) I 8-2218 (C) Figure 3. Typical JC100A Input Characteristics ...

Page 6

... OUTPUT CURRENT, I Figure 6. Typical JC100A Output Characteristics at Room Temperature (continued (A) O Figure 7. Typical JC050A Converter Efficiency vs. 8-1598 ( (A) O 8-1599 (C) Figure 8. Typical JC075A Converter Efficiency vs. March 2008 OUTPUT CURRENT Output Current at Room Temperature OUTPUT CURRENT Output Current at Room Temperature Lineage Power (A) 8-1600 ( (A) 8-1601 (C) ...

Page 7

... OUTPUT CURRENT, I Figure 9. Typical JC100A Converter Efficiency vs. Output Current at Room Temperature μs/div) TIME Figure 10.Typical JC100A Output Ripple Voltage at Room Temperature and 20 A Output Lineage Power 18 Vdc to 36 Vdc Input, 5 Vdc Output 100 Figure 11.Typical JC100A Transient Response to (A) O Step Decrease in Load from 50% to 25% ...

Page 8

... Vdc to 36 Vdc Input, 5 Vdc Output 100 W Characteristic Curves TIME ms/div) Figure 13.Typical Start-Up from Remote On/Off JC100A1 Full Load O Test Configurations TO OSCILLOSCOPE L TEST 12 µH C 220 µF S ESR < 0.1 Ω BATTERY @ 20 ˚C, 100 kHz Note: Measure input reflected-ripple current with a simulated source inductance ( µ ...

Page 9

... The unit operates normally once the output current is brought back into its specified range. Lineage Power 18 Vdc to 36 Vdc Input, 5 Vdc Output 100 W Feature Descriptions Remote On/Off Two remote on/off options are available ...

Page 10

... March 2008 (+) and (+) V (+) I O ON/OFF SENSE(+) CASE TRIM R adj-down V (–) SENSE(– (–) O Output Voltage 1M 100k 10k 1k 100 CHANGE IN OUTPUT VOLTAGE (Δ%) Output Voltage Lineage Power (–) terminals O R LOAD 8-748 (C). 8-879 (C) ...

Page 11

... Feature specifications table). this provides a redundant voltage control that reduces the risk of output overvoltage. Lineage Power 18 Vdc to 36 Vdc Input, 5 Vdc Output 100 W Overtermperature Protection (Shutdown) The 100 W module features an overtemperature pro- tection circuit to safeguard against thermal damage ...

Page 12

... A 8-1150 (C).a Figure 27. JC100A Power Dissipation vs. March 2008 OUTPUT CURRENT Output Current OUTPUT CURRENT, I (A) O Output Current OUTPUT CURRENT, I (A) O Output Current Lineage Power (A) 8-2220 8-1604 8-1605 ...

Page 13

... The module used to collect the data in Figure 28 had a Lineage Power 18 Vdc to 36 Vdc Input, 5 Vdc Output 100 W thermal-conductive dry pad between the case and the (continued) heat sink to minimize contact resistance ...

Page 14

... This equation pro vides a conservative estimate for such instances θsa Layout Considerations 8-1304 Copper paths must not be routed beneath the power module mounting inserts. March 2008 ( ) T – θ θ ------------------------ - – Lineage Power ...

Page 15

... TRIM ON/OFF +SEN V (+) V (+) I O 48.26 (1.900) 4.8 48.3 (1.90) (0.19) March 2008 2.06 (0.081) DIA SOLDER-PLATED BRASS, 2 PLACES–(OUTPUT AND +OUTPUT) MOUNTING INSERTS M3 x 0.5 THROUGH, 4 PLACES 10.16 (0.400) 17.78 (0.700) 25.40 (1.000) 35.56 (1.400) Lineage Power 8-1945 ...

Page 16

... Ind ia Head qu arters T el: + 28411633 March 2008 35.56 (1.400) 25.40 (1.000) 61.0 17.78 (2.40) 10.16 (0.700) MAX (0.400) MOUNTING INSERTS 3.30 ± 0.15 (0.130 ± 0.005) Device Comcode Code JC050A1 107201634 JC075A1 107309999 JC100A1 107201675 JC050A 107309858 JC075A 107430340 JC100A 107309924 8-1945 ...

Related keywords