APXS002A0X-SRZ Lineage Power, APXS002A0X-SRZ Datasheet - Page 2

PWR MOD DC/DC 0.59-5.5V @ 2A SMD

APXS002A0X-SRZ

Manufacturer Part Number
APXS002A0X-SRZ
Description
PWR MOD DC/DC 0.59-5.5V @ 2A SMD
Manufacturer
Lineage Power
Series
Pico TLynx™r
Type
Point of Load (POL) Non-Isolated with Remote On/Offr
Datasheet

Specifications of APXS002A0X-SRZ

Output
0.6 ~ 5.5V
Number Of Outputs
1
Power (watts)
15W
Mounting Type
Surface Mount
Voltage - Input
3 ~ 14V
Package / Case
10-SMD Module
1st Output
0.6 ~ 5.5 VDC @ 2A
Size / Dimension
0.48" L x 0.48" W x 0.25" H (12.2mm x 12.2mm x 6.3mm)
Power (watts) - Rated
11W
Operating Temperature
-40°C ~ 85°C
Efficiency
93%
Approvals
CSA, EN, UL, VDE
Input Voltage Range
3 V to 14 V
Input Voltage (nominal)
12 V
Output Voltage (channel 1)
0.6 V to 5.5 V
Output Current (channel 1)
2 A
Package / Case Size
12.2 mm x 12.2 mm x 6.25 mm
Output Type
Non-Isolated
Output Voltage
0.6 V to 5.5 V
Product
Non-Isolated / POL
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
3rd Output
-
2nd Output
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
555-1160-2

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
APXS002A0X-SRZ
Manufacturer:
GECRITICALPOWER
Quantity:
20 000
Data Sheet
March 31, 2011
Absolute Maximum Ratings
Stresses in excess of the absolute maximum ratings can cause permanent damage to the device. These are
absolute stress ratings only, functional operation of the device is not implied at these or any other conditions in
excess of those given in the operations sections of the data sheet. Exposure to absolute maximum ratings for
extended periods can adversely affect the device reliability.
Electrical Specifications
Unless otherwise indicated, specifications apply over all operating input voltage, resistive load, and temperature
conditions.
CAUTION: This power module is not internally fused. An input line fuse must always be used.
This power module can be used in a wide variety of applications, ranging from simple standalone operation to an
integrated part of sophisticated power architecture. To preserve maximum flexibility, internal fusing is not included;
however, to achieve maximum safety and system protection, always use an input line fuse. The safety agencies
require a fast-acting fuse with a maximum rating of 4A (see Safety Considerations section). Based on the information
provided in this data sheet on inrush energy and maximum dc input current, the same type of fuse with a lower rating
can be used. Refer to the fuse manufacturer’s data sheet for further information.
LINEAGE
Parameter
Input Voltage
Operating Ambient Temperature
Storage Temperature
Parameter
Operating Input Voltage
Maximum Input Current
Input No Load Current
Input Stand-by Current
Inrush Transient
Input Reflected Ripple Current, peak-to-peak
(5Hz to 20MHz, 1μH source impedance; V
to 14V
Input Ripple Rejection (120Hz)
Continuous
(see Thermal Considerations section)
(V
(V
(V
IN
IN
IN
=3V to 14V, I
= 12.0Vdc, I
= 12.0Vdc, module disabled)
,
I
O
= I
POWER
Omax
; See Test Configurations)
O
O
=I
= 0, module enabled)
O, max
)
IN
3 – 14Vdc input; 0.6Vdc to 5.5Vdc output; 2A output current
= 0
12V Pico TLynx
V
V
O,set
O,set
Device
= 0.6 Vdc
= 5.5Vdc
All
All
All
All
All
All
Device
All
All
All
TM
2A: Non-isolated DC-DC Power Modules
Symbol
I
I
I
IN,stand-by
IN,No load
IN,No load
I
IN,max
V
I
Symbol
2
IN
t
T
V
T
stg
IN
A
Min
3.0
Min
-0.3
-40
-55
Typ
-65
20
48
20
8
Max
125
15
85
1.8A
Max
14.0
1
mAp-p
dB
Unit
Vdc
°C
°C
Unit
Vdc
Adc
mA
mA
mA
A
2
s
2

Related parts for APXS002A0X-SRZ