AXH003A0X-SRZ Lineage Power, AXH003A0X-SRZ Datasheet - Page 12

CONVER DC/DC 0.75 3.63V @ 3A SMD

AXH003A0X-SRZ

Manufacturer Part Number
AXH003A0X-SRZ
Description
CONVER DC/DC 0.75 3.63V @ 3A SMD
Manufacturer
Lineage Power
Series
Austin MiniLynx™r
Type
Point of Load (POL) Non-Isolated with Remote On/Offr
Datasheet

Specifications of AXH003A0X-SRZ

Output
0.75 ~ 3.63V
Number Of Outputs
1
Power (watts)
10W
Mounting Type
Surface Mount
Voltage - Input
2.4 ~ 5.5V
Package / Case
5-SMD Module
1st Output
0.75 ~ 3.63 VDC @ 3A
Size / Dimension
0.80" L x 0.45" W x 0.29" H (20.3mm x 11.4mm x 7.3mm)
Power (watts) - Rated
10W
Operating Temperature
-40°C ~ 85°C
Efficiency
94%
Approvals
CSA, EN, UL, VDE
Output Power
11 W
Input Voltage Range
2.4 V to 5.5 V
Output Voltage (channel 1)
0.75 V to 3.63 V
Output Current (channel 1)
3 A
Package / Case Size
SMD
Output Type
Non-Isolated
Output Voltage
0.75 V to 3.63 V
Product
Non-Isolated / POL
Output Current
3A
Input Voltage
2.4 to 5.5V
Screening Level
Industrial
Product Length (mm)
20.3mm
Product Depth (mm)
11.4mm
Mounting Style
Surface Mount
Pin Count
5
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
3rd Output
-
2nd Output
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
555-1053-2
CC109101301

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
AXH003A0X-SRZ
Manufacturer:
LINEAGE
Quantity:
20 000
Data Sheet
October 2, 2009
Feature Description
Remote On/Off
The Austin MiniLynx
an On/Off pin for remote On/Off operation. Two
On/Off logic options are available in the Austin
MiniLynx
signal, device code suffix “4”, turns the module ON
during a logic High on the On/Off pin and turns the
module OFF during a logic Low. Negative logic
On/Off signal, no device code suffix, turns the module
OFF during logic High on the On/Off pin and turns the
module ON during logic Low.
For positive logic modules, the circuit configuration for
using the On/Off pin is shown in Figure 30. The
On/Off pin is an open collector/drain logic input signal
(Von/Off) that is referenced to ground. During a logic-
high (On/Off pin is pulled high internal to the module)
when the transistor Q1 is in the Off state, the power
module is ON. Maximum allowable leakage current of
the transistor when Von/off = V
Applying a logic-low when the transistor Q1 is turned-
On, the power module is OFF. During this state
VOn/Off must be less than 0.3V. When not using
positive logic On/off pin, leave the pin unconnected or
tie to V
Figure 30. Circuit configuration for using positive
logic On/OFF.
For negative logic On/Off devices, the circuit
configuration is shown is Figure 31. The On/Off pin is
pulled high with an external pull-up resistor (typical
R
state, logic High is applied to the On/Off pin and the
power module is Off. The minimum On/off voltage for
logic High on the On/Off pin is 1.5Vdc. To turn the
module ON, logic Low is applied to the On/Off pin by
turning ON Q1. When not using the negative logic
On/Off, leave the pin unconnected or tie to GND.
LINEAGE
I
pull-up
ON/OFF
GND
VIN+
= 5k, +/- 5%). When transistor Q1 is in the Off
IN.
ON/OFF
TM
V
Q1
ON/OFF
POWER
series modules. Positive Logic On/Off
+
_
TM
R1
SMT power modules feature
R2
R3
R4
IN,max
2.4 – 5.5Vdc input; 0.75Vdc to 3.63Vdc Output; 3A output current
Q2
is 10µA.
MODULE
PWM Enable
Q3
CSS
Austin MiniLynx
Figure 31. Circuit configuration for using
negative logic On/OFF.
Overcurrent Protection
To provide protection in a fault (output overload)
condition, the unit is equipped with internal
current-limiting circuitry and can endure current
limiting continuously. At the point of current-limit
inception, the unit enters hiccup mode. The unit
operates normally once the output current is brought
back into its specified range. The typical average
output current during hiccup is 2A.
Input Undervoltage Lockout
At input voltages below the input undervoltage lockout
limit, module operation is disabled. The module will
begin to operate at an input voltage above the
undervoltage lockout turn-on threshold.
Overtemperature Protection
To provide over temperature protection in a fault
condition, the unit relies upon the thermal
protection feature of the controller IC. The unit will
shutdown if the thermal reference point T
exceeds 140
is not intended as a guarantee that the unit will
survive temperatures beyond its rating. The
module will automatically restart after it cools down.
Output Voltage Programming
The output voltage of the Austin MiniLynx
be programmed to any voltage from 0.75 Vdc to 3.63
Vdc by connecting a single resistor (shown as Rtrim
in Figure 32) between the TRIM and GND pins of the
module. Without an external resistor between TRIM
pin and the ground, the output voltage of the module
is 0.7525 Vdc. To calculate the value of the resistor
Rtrim for a particular output voltage Vo, use the
following equation:
ON/OFF
VIN+
GND
TM
SMT Non-isolated Power Modules:
V
Q1
R
I
ON/OFF
Rtrim
pull-up
ON/OFF
o
+
_
C (typical), but the thermal shutdown
=
Vo
21070
. 0
7525
R1
R2
MODULE
5110
PWM Enable
Q2
ref
Ω
TM
,
SMT can
CSS
12

Related parts for AXH003A0X-SRZ