AXA003A0X4 Lineage Power, AXA003A0X4 Datasheet - Page 14

CONVERT DC/DC 0.75 5.5V @ 3A SIP

AXA003A0X4

Manufacturer Part Number
AXA003A0X4
Description
CONVERT DC/DC 0.75 5.5V @ 3A SIP
Manufacturer
Lineage Power
Series
Austin MiniLynx™r
Type
Point of Load (POL) Non-Isolated with Remote On/Offr
Datasheet

Specifications of AXA003A0X4

Rohs Status
RoHS non-compliant
Output
0.75 ~ 5.5V
Number Of Outputs
1
Power (watts)
16W
Mounting Type
Through Hole
Voltage - Input
8.3 ~ 14V
Package / Case
5-SIP Module
1st Output
0.75 ~ 5.5 VDC @ 3A
Size / Dimension
0.90" L x 0.26" W x 0.40" H (22.9mm x 6.6mm x 10.2mm)
Power (watts) - Rated
16.5W
Operating Temperature
-40°C ~ 85°C
Efficiency
91%
Approvals
CSA, EN, UL, VDE
Product
Non-Isolated / POL
3rd Output
-
2nd Output
-
Lead Free Status / Rohs Status
No RoHS Version Available
Other names
555-1003

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
AXA003A0X4-SR
Manufacturer:
OK
Quantity:
2 368
Part Number:
AXA003A0X4-SR
Manufacturer:
PWR
Quantity:
20 000
Data Sheet
October 2, 2009
Thermal Considerations
Power modules operate in a variety of thermal
environments; however, sufficient cooling should be
provided to help ensure reliable operation.
Considerations include ambient temperature, airflow,
module power dissipation, and the need for increased
reliability. A reduction in the operating temperature of
the module will result in an increase in reliability. The
thermal data presented here is based on physical
measurements taken in a wind tunnel. The test set-
up is shown in Figure 32. Note that the airflow is
parallel to the long axis of the module as shown in
figure 31. The derating data applies to airflow in
either direction of the module’s long axis.
Figure 31. T ref Temperature measurement
location.
The thermal reference point, T
specifications is shown in Figure 32. For reliable
operation this temperature should not exceed 115
The output power of the module should not exceed
the rated power of the module (Vo,set x Io,max).
Please refer to the Application Note “Thermal
Characterization Process For Open-Frame Board-
Mounted Power Modules” for a detailed discussion of
thermal aspects including maximum device
temperatures.
LINEAGE
Airflow
POWER
Tref2
Tref1
ref
used in the
8.3 – 14Vdc Input; 0.75Vdc to 5.5Vdc Output; 3A output current
Austin MiniLynx
o
C.
Heat Transfer via Convection
Increased airflow over the module enhances the heat
transfer via convection. Thermal derating curves
showing the maximum output current that can be
delivered by various module versus local ambient
temperature (T
0.5m/s (100 ft./min) are shown in the Characteristics
Curves section.
TM
Wind T unnel
12V SIP Non-isolated Power Modules:
PWBs
Figure 32. Thermal Test Set-up.
A
) for natural convection and up to
flow
Air
(0.235)
x
5.97_
(3.0)
76.2_
25.4_
(1.0)
Probe Loc ation
for measuring
airflow and
ambient
temperature
Power Module
14