APXW005A0X3-SRZ Lineage Power, APXW005A0X3-SRZ Datasheet - Page 12

PWR MOD DC/DC NON-ISOL 9-36V 5A

APXW005A0X3-SRZ

Manufacturer Part Number
APXW005A0X3-SRZ
Description
PWR MOD DC/DC NON-ISOL 9-36V 5A
Manufacturer
Lineage Power
Series
ProLynx™r
Type
Point of Load (POL) Non-Isolated with Remote On/Offr
Datasheet

Specifications of APXW005A0X3-SRZ

Output
3 ~ 18V
Number Of Outputs
1
Power (watts)
90W
Mounting Type
Surface Mount
Voltage - Input
9 ~ 36V
Package / Case
7-SMD Module
1st Output
3 ~ 18 VDC @ 5A
Size / Dimension
0.80" L x 0.45" W x 0.34" H (20.3mm x 11.4mm x 8.5mm)
Operating Temperature
-40°C ~ 85°C
Efficiency
95.9%
Approvals
CSA, EN, UL, VDE
Input Voltage Range
9 V to 36 V
Output Voltage (channel 1)
3 VDC to 18 VDC
Output Current (channel 1)
2.5 A to 5 A
Package / Case Size
20.3 mm x 11.4 mm x 8.5 mm
Output Type
Non-Isolated
Output Voltage
3 VDC to 18 VDC
Product
Non-Isolated / POL
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
3rd Output
-
2nd Output
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
555-1172-2
CC109151916

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
APXW005A0X3-SRZ
Manufacturer:
GENERGY
Quantity:
120
Part Number:
APXW005A0X3-SRZ
Manufacturer:
GEENER
Quantity:
20 000
Company:
Part Number:
APXW005A0X3-SRZ
Quantity:
750
Preliminary Data Sheet
October 28, 2010
Feature Descriptions
Remote Enable
The 9-36V ProLynx
remote On/Off operation. Two On/Off logic options are
available. In the Positive Logic On/Off option, (device
code suffix “4” – see Ordering Information), the module
turns ON during a logic High on the On/Off pin and turns
OFF during a logic Low.
On/Off option, (no device code suffix, see Ordering
Information), the module turns OFF during logic High
and ON during logic Low. The On/Off signal is always
referenced to ground.
For positive logic modules, the circuit configuration for
using the On/Off pin is shown in Figure 32. When the
external transistor Q1 is in the OFF state, the ON/OFF
pin is pulled high and transistor Q2 is OFF leading to Q3
also being OFF which turns the module ON. The
external resistor R
sized so that V
is OFF. In particular, if V
input voltage Vin, the resistor R
enough so that V
For
configuration is shown in Fig. 33. When the external
transistor Q1 is in the ON state, the ON/OFF pin is
pulled low causing transistor Q2 to be OFF and the
module to be turned ON. To turn the module OFF, Q1 is
turned OFF, causing the ON/OFF pin to be pulled high
turing Q2 ON and the module to be turned OFF.
Leaving the On/Off pin floating will leave the module in
an OFF state.
Figure 32. Circuit configuration for using positive
On/Off logic.
LINEAGE
Vpullup
negative
Rpullup
Q1
GND
I
ON/OFF
ON/OFF
V
ON/OFF
POWER
+
_
ON/OFF
MODULE
logic
ON/OFF
22K
pullup
TM
is never more than 12V when Q1
modules feature an On/Off pin for
is never more than 12V.
22K
On/Off
(100k recommended) must be
pullup
Q2
With the Negative Logic
is made the same as the
42K
9 – 36Vdc input; 3Vdc to 18Vdc output; 5A to 2.5A output current
22K
modules,
+5V
pullup
Q3
must be large
9-36V ProLynx
PWM Enable
the
CSS
circuit
Figure 33. Circuit configuration for using negative
On/Off logic.
Overcurrent Protection
To provide protection in a fault (output overload)
condition, the unit is equipped with internal
current-limiting circuitry and can endure current limiting
continuously. At the point of current-limit inception, the
unit enters hiccup mode. The unit operates normally
once the output current is brought back into its specified
range. The 9-36V ProLynx modules employ an
innovative, patent pending, ‘AutoLimit’ capability. This
results in automatic scaling of current limit with output
voltage through an inverse relationship of the current
limit threshold with the output voltage. This feature
shown graphically in Fig. 34, allows higher output
currents to be drawn from the module at lower output
voltages thereby optimizing the power delivery
capability of the module.
Figure 34. Graph showing maximum output current
capability at different output voltages.
Over Temperature Protection
To provide protection in a fault condition, the unit is
equipped with a thermal shutdown circuit. The unit will
shutdown if the overtemperature threshold of 130
exceeded at the thermal reference point T
thermal shutdown is not intended as a guarantee that
the unit will survive temperatures beyond its rating.
ON/OFF
TM
VIN+
5.5
4.5
3.5
2.5
5A: Non-isolated DC-DC Power Modules
5
4
3
2
3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18
Rpullup
Q1
GND
I
ON/OFF
V
ON/OFF
_
+
MODULE
22K
Output Voltage (V)
D1
D2
22K
22K
22K
+5V
ref.
PWM Enable
Q2
The
CSS
o
C is
12

Related parts for APXW005A0X3-SRZ