ATH030A0X3Z Lineage Power, ATH030A0X3Z Datasheet

CONVER DC/DC 0.8 3.63V @ 30A SIP

ATH030A0X3Z

Manufacturer Part Number
ATH030A0X3Z
Description
CONVER DC/DC 0.8 3.63V @ 30A SIP
Manufacturer
Lineage Power
Series
Austin MegaLynx™r
Type
Point of Load (POL) Non-Isolated with Remote On/Offr
Datasheet

Specifications of ATH030A0X3Z

Output
0.8 ~ 3.63V
Number Of Outputs
1
Power (watts)
108W
Mounting Type
Through Hole
Voltage - Input
4.5 ~ 5.5V
Package / Case
13-SIP Module
1st Output
0.8 ~ 3.63 VDC @ 30A
Size / Dimension
2.00" L x 0.55" W x 0.50" H (50.8mm x 14mm x 12.7mm)
Power (watts) - Rated
108W
Operating Temperature
-40°C ~ 85°C
Efficiency
93%
Approvals
CSA, EN, UL, VDE
Product
Non-Isolated / POL
Output Power
109 W
Input Voltage Range
4.5 V to 5.5 V
Output Voltage (channel 1)
0.8 V to 3.63 V
Output Current (channel 1)
30 A
Package / Case Size
SIP
Output Type
Non-Isolated
Output Voltage
0.8 V to 3.63 V
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
3rd Output
-
2nd Output
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
555-1094
CC109104782
Applications
Description
The Austin MegaLynx series SIP power modules are non-isolated DC-DC converters in an industry standard
package that can deliver up to 30A of output current with a full load efficiency of 92% at 3.3Vdc output voltage (V
12Vdc). The ATH series of modules operate off an input voltage from 4.5 to 5.5Vdc and provide an output voltage
that is programmable from 0.8 to 3.63Vdc, while the ATS series of modules have an input voltage range from 6 to
14V and provide a programmable output voltage ranging from 0.8 to 5.5Vdc. Both series have a sequencing feature
that enables designers to implement various types of output voltage sequencing when powering multiple modules
on the board. Additional features include remote On/Off, adjustable output voltage, remote sense, over current,
over temperature protection and active current sharing between modules.
*
** ISO is a registered trademark of the International Organization of Standards
Data Sheet
October 2, 2009
UL is a registered trademark of Underwriters Laboratories, Inc.
CSA is a registered trademark of Canadian Standards Association.
VDE is a trademark of Verband Deutscher Elektrotechniker e.V.
Distributed power architectures
Intermediate bus voltage applications
Telecommunications equipment
Servers and storage applications
Networking equipment
6.0 – 14Vdc input; 0.8dc to 5.5Vdc output; 25A Output Current
4.5 – 5.5Vdc input; 0.8 to 3.63Vdc output; 30A Output Current
Austin MegaLynx
RoHS Compliant
TM
: Non-Isolated DC-DC Power Modules:
Features
Compliant to RoHS EU Directive 2002/95/EC (-
Z versions)
Compliant to ROHS EU Directive 2002/95/EC
with lead solder exemption (non-Z versions)
Delivers up to 30A of output current
High efficiency – 93% 3.3V full load (V
Available in two input voltage ranges
Output voltage programmable from
Small size and low profile:
Monotonic start-up into pre-biased output
Output voltage sequencing (EZ-SEQUENCE
Remote On/Off
Remote Sense
Over current and Over temperature protection
Parallel operation with active current sharing
Wide operating temperature range (-40°C to
85°C)
UL* 60950 Recognized, CSA
60950-00 Certified, and VDE
3
ISO** 9001 and ISO 14001 certified
manufacturing facilities
rd
edition) Licensed
ATH: 4.5 to 5.5Vdc
ATS: 6.0 to 14Vdc
ATH: 0.8 to 3.63Vdc
ATS: 0.8 to 5.5Vdc
50.8 mm x 12.7 mm x 14.0 mm
2.00 in. x 0.50 in. x 0.55 in.
PDF Name: austin_megalynx_sip.pdf
Document No: DS05-012 ver. 1.05
0805 (EN60950-1
C22.2 No.
IN
=12Vdc)
IN
TM
=
)

Related parts for ATH030A0X3Z

ATH030A0X3Z Summary of contents

Page 1

Data Sheet October 2, 2009 Austin MegaLynx 4.5 – 5.5Vdc input; 0.8 to 3.63Vdc output; 30A Output Current 6.0 – 14Vdc input; 0.8dc to 5.5Vdc output; 25A Output Current RoHS Compliant Applications Distributed power architectures Intermediate bus voltage applications Telecommunications ...

Page 2

Data Sheet October 2, 2009 Absolute Maximum Ratings Stresses in excess of the absolute maximum ratings can cause permanent damage to the device. These are absolute stress ratings only, functional operation of the device is not implied at these or ...

Page 3

Data Sheet October 2, 2009 Electrical Specifications (continued) Parameter Output Voltage Set-point ( =25°C) IN IN,min O O, max ref Output Voltage (Over all operating input voltage, resistive load, and temperature conditions until end ...

Page 4

Data Sheet October 2, 2009 Electrical Specifications (continued) Parameter Dynamic Load Response (dI /dt=5A/μ =3.3V nom O Load Change from Io 50 external output capacitors Peak ...

Page 5

Data Sheet October 2, 2009 Feature Specifications Unless otherwise indicated, specifications apply over all operating input voltage, resistive load, and temperature conditions. See Feature Descriptions for additional information. Parameter On/Off Signal Interface ( open collector or ...

Page 6

Data Sheet October 2, 2009 Characteristic Curves The following figures provide typical characteristics for the ATS025A0X (0.8V, 25A 92% 89% 86% 83% 80% 77% 74% 71% 68 OUTPUT CURRENT, I Figure 1. Converter Efficiency versus ...

Page 7

Data Sheet October 2, 2009 Characteristic Curves The following figures provide typical characteristics for the ATS025A0X (1.8V, 25A 96% 93% 90% 87% 84% 81% 78% 75% 72 OUTPUT CURRENT, I Figure 7. Converter Efficiency versus ...

Page 8

Data Sheet October 2, 2009 Characteristic Curves The following figures provide typical characteristics for the ATS025A0X (3.3V, 25A 99% 96% 93% 90% 87% 84% 81% 78% 75 OUTPUT CURRENT, I Figure 13. Converter Efficiency versus ...

Page 9

Data Sheet October 2, 2009 Characteristic Curves The following figures provide typical characteristics for the ATH030A0X (0.8V, 30A 92% 89% 86% 83% 80% 77% 74% 71% 68 OUTPUT CURRENT, I Figure 19. Converter Efficiency versus ...

Page 10

Data Sheet October 2, 2009 Characteristic Curves The following figures provide typical characteristics for the ATH030A0X (1.8V, 30A 96% 93% 90% 87% 84% 81% 78% 75% 72 OUTPUT CURRENT, I Figure 25. Converter Efficiency versus ...

Page 11

Data Sheet October 2, 2009 Characteristic Curves The following figures provide typical characteristics for the ATH030A0X (3.3V, 30A 99% 96% 93% 90% 87% 84% 81% 78% 75 OUTPUT CURRENT, I Figure 31. Converter Efficiency versus ...

Page 12

Data Sheet October 2, 2009 Test Configurations TO OSCILLOSCOPE L TEST 1μ 220μF S Min E.S.R.<0.1Ω 150μF @ 20°C 100kHz NOTE: Measure input reflected ripple current with a simulated source inductance ( 1μH. Capacitor C ...

Page 13

Data Sheet October 2, 2009 Safety Considerations For safety agency approval the power module must be installed in compliance with the spacing and separation requirements of the end-use safety agency standards, i.e., UL 60950, CSA C22.2 No. 60950-00, EN60950 rd ...

Page 14

... Programming Tool, available at under the Design Tools section, also calculates the values of R margin-up voltage and % margin. Please consult your local Lineage Power technical representative for additional details. under the Design Voltage Sequencing The Austin MegaLynx series of modules include a sequencing feature that enables users to implement various types of output voltage sequencing in their applications ...

Page 15

Data Sheet October 2, 2009 For proper voltage sequencing, first, input voltage is applied to the module. The On/Off pin of the module is left unconnected or tied to GND for negative logic modules so that the module is ON ...

Page 16

Data Sheet October 2, 2009 Thermal Considerations Power modules operate in a variety of thermal environments; however, sufficient cooling should always be provided to help ensure reliable operation. Considerations include ambient temperature, airflow, module power dissipation, and the need for ...

Page 17

Data Sheet October 2, 2009 Mechanical Outline of Module Dimensions are in millimeters and (inches). Tolerances: x.x mm ± 0.5 mm (x.xx in. ± 0.02 in.) [unless otherwise indicated] x.xx mm ± 0.25 mm (x.xxx in ± 0.010 in) Pin ...

Page 18

Data Sheet October 2, 2009 Recommended Pad Layout Dimensions are in millimeters and (inches). Tolerances: x.x mm ± 0.5 mm (x.xx in. ± 0.02 in.) [unless otherwise indicated] x.xx mm ± 0.25 mm (x.xxx in ± 0.010 in) LINEAGE POWER ...

Page 19

... For Pb solder, the recommended pot temperature is 260°C, while the Pb-free solder pot is 270°C max. Not all RoHS-compliant through-hole products can be processed with paste-through-hole Pb or Pb-free reflow process. If additional information is needed, please consult with your Lineage Power technical representative for more details. LINEAGE POWER TM ...

Page 20

... Asia-Pacific Headquarters Tel: +65 6593 7211 Europe, Middle-East and Africa Headquarters Tel: +49 898 780 672 80 India Headquarters Tel: +91 80 28411633 Product codes Comcodes ATH025A0X3 108991980 ATH025A0X3Z CC109104774 ATH030A0X3 108992005 ATH030A0X3Z CC109104782 ATH030A0X3-P 108993358 ATH030A0X3-PZ CC109104790 ATS025A0X3 108991997 ATS025A0X3Z CC109104808 ATS025A0X53 108997210 ATS025A0X3-P 108993341 ...

Related keywords