HS2282ECF61H Renesas Electronics America, HS2282ECF61H Datasheet

no-image

HS2282ECF61H

Manufacturer Part Number
HS2282ECF61H
Description
DEV EMULATOR PCB ADAPTOR 100-QFP
Manufacturer
Renesas Electronics America
Datasheet

Specifications of HS2282ECF61H

Accessory Type
User Interface Cable
For Use With/related Products
H8S/2282
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
To our customers,
Corporation, and Renesas Electronics Corporation took over all the business of both
companies. Therefore, although the old company name remains in this document, it is a valid
Renesas Electronics document. We appreciate your understanding.
Issued by: Renesas Electronics Corporation (http://www.renesas.com)
Send any inquiries to http://www.renesas.com/inquiry.
On April 1
st
, 2010, NEC Electronics Corporation merged with Renesas Technology
Renesas Electronics website:
Old Company Name in Catalogs and Other Documents
http://www.renesas.com
April 1
Renesas Electronics Corporation
st
, 2010

Related parts for HS2282ECF61H

HS2282ECF61H Summary of contents

Page 1

To our customers, Old Company Name in Catalogs and Other Documents st On April 1 , 2010, NEC Electronics Corporation merged with Renesas Technology Corporation, and Renesas Electronics Corporation took over all the business of both companies. Therefore, although the ...

Page 2

All information included in this document is current as of the date this document is issued. Such information, however, is subject to change without any prior notice. Before purchasing or using any Renesas Electronics products listed herein, please confirm ...

Page 3

To all our customers Regarding the change of names mentioned in the document, such as Hitachi Electric and Hitachi XX, to Renesas Technology Corp. The semiconductor operations of Mitsubishi Electric and Hitachi were transferred to Renesas Technology Corporation on April ...

Page 4

Cautions Keep safety first in your circuit designs! 1. Renesas Technology Corporation puts the maximum effort into making semiconductor products better and more reliable, but there is always the possibility that trouble may occur with them. Trouble with semiconductors may ...

Page 5

... H8S/2282 Series FP-100A User System Interface Cable (HS2282ECF61H) for E6000 Emulator User’s Manual Rev.2.0 2002.02 ...

Page 6

...

Page 7

Hitachi neither warrants nor grants licenses of any rights of Hitachi’s or any third party’s patent, copyright, trademark, or other intellectual property rights for information contained in this document. Hitachi bears no responsibility for problems that may arise with ...

Page 8

...

Page 9

... Throughout this document, the term "user system interface cable" shall be defined as the following product produced only by Hitachi, Ltd. excluding all subsidiary products. User system interface cable (HS2282ECF61H) The user system or a host computer is not included in this definition. Purpose of the User System Interface Cable: This user system interface cable is for connecting the emulator station and user system ...

Page 10

LIMITED WARRANTY Hitachi warrants its user system interface cables to be manufactured in accordance with published specifications and free from defects in material and/or workmanship. Hitachi will repair or replace any user system interface cables determined to be defective in ...

Page 11

State Law: Some states do not allow the exclusion or limitation of implied warranties or liability for incidental or consequential damages, so the above limitation or exclusion may not apply to you. This warranty gives you specific legal rights, and ...

Page 12

READ this user's manual before using this user system interface cable. • KEEP the user's manual handy for future reference. Do not attempt to use the user system interface cable until you fully understand its mechanism. DEFINITION OF SIGNAL ...

Page 13

Observe the precautions listed below. Failure will result in a FIRE HAZARD and will damage the user system and the emulator product or will result in PERSONAL INJURY. The USER PROGRAM will be LOST not ...

Page 14

... Thank you for purchasing this user system interface cable (HS2282ECF61H) for the Hitachi’s original microcomputer H8S/2282 series. The HS2282ECF61H is a user system interface cable that connects an H8S/2636, H8S/2646 series E6000 emulator (HS2646EPI61H; hereinafter referred to as the emulator) to the IC socket for an FP-100A package for the H8S/2282 series MCU on the user system ...

Page 15

Section 1 Configuration....................................................................................1 Section 2 Connection Procedures ......................................................................3 2.1 Connecting User System Interface Cable to Emulator Station .......................................... 3 2.2 Connecting User System Interface Cable to User System................................................. 5 Installing IC Socket.............................................................................................. 5 2.2.1 2.2.2 Soldering IC Socket ............................................................................................. 5 ...

Page 16

... Use an IC149-KS-11113-0 socket (manufactured by YAMAICHI ELECTRONICS Co., Ltd.) for the FP-100A package IC socket on the user system. Figure 1 shows the configuration of the HS2282ECF61H user system interface cable for the FP-100A package. Figure 1 HS2282ECF61H User System Interface Cable Table 1 lists the HS2282ECF61H components. Please make sure you have all of these components when unpacking ...

Page 17

... Table 1 HS2282ECF61H Components No. Component 1 Cable body 2 Cable head 3 IC socket 4 Socket cover 5 Screws (M2 mm) 6 Documentation 2 Quantity Remarks 1 Flat cable 1 1 For the FP-100A package 1 For installing an FP-100A packaged MCU 2 For fastening cable head 1 User’s manual for HS2282ECF61H (this manual) ...

Page 18

Section 2 Connection Procedures 2.1 Connecting User System Interface Cable to Emulator Station Observe the precautions listed below. Failure will result in a FIRE HAZARD and will damage the user system and the emulator product or will ...

Page 19

Figure 2 Connecting User System Interface Cable to Emulator Station 4 ...

Page 20

Connecting User System Interface Cable to User System Always switch OFF the user system and the emulator product before the USER SYSTEM INTERFACE CABLE is connected to or removed from any part. Before connecting, make sure that pin 1 ...

Page 21

Fastening Cable Head 1. Use a Phillips-type screwdriver whose head matches the screw head. 2. The tightening torque must be 0.098 N•m or less. If the applied torque cannot be accurately measured, stop tightening when the force required to ...

Page 22

Fasten the user system interface cable head to the IC socket for an FP-100A package on the user system with the two screws (M2.5 time, alternating between screws on opposing corners. Take special care, such as manually securing the IC ...

Page 23

Fastening Cable Body Connect the cable body to the cable head. Cable body User system 8 Remove jig Cable head Figure 4 Fastening Cable Body Removing Push the remove jig. ...

Page 24

Recommended Dimensions for User System Mount Pad Figure 5 shows the recommended dimensions for the mount pad (footprint) for the user system with an IC socket for an FP-100A package (IC149-KS-11113-0: manufactured by YAMAICHI ELECTRONICS Co., Ltd.). Note that ...

Page 25

Dimensions for User System Interface Cable Head The dimensions for the user system interface cable head are shown in figure 6. Figure 6 Dimensions for User System Interface Cable Head 10 ...

Page 26

Resulting Dimensions after Connecting User System Interface Cable The resulting dimensions, after connecting the user system interface cable head to the user system, are shown in figure 7. Figure 7 Resulting Dimensions after Connecting User System Interface Cable 11 ...

Page 27

Section 3 Installing the MCU to the User System 1. Check the location of pin 1 before inserting the MCU does not operate correctly, cracks might have occurred in the solder. Check conduction with a tester and re-solder ...

Page 28

Section 4 Verifying Operation 1. When using the E6000 emulator for the H8S/2636 and H8S/2646 series, turn on the emulator according to the procedures described in the H8S Series E6000 Emulator User's Manual (HS2000EPI61HE). 2. Verify the user system interface ...

Page 29

Section 5 Setting TRPB2, TRPA2, TRPA1, and TRPB1 In this user system interface cable, TRPB2, TRPA2, TRPA1, and TRPB1 switches control the transport register (TRPRT) of the MCU. Set this function with these switches because the register write is not ...

Page 30

Make sure that pin 1 on the user system IC socket is correctly aligned with pin 1 on the cable head before inserting the cable head into the user system IC socket. 2. The dimensions of the recommended mount ...

Page 31

The P1 short connector is used for testing. Do not remove the inserted jumper pin. 16 Figure 12 P1 Short Connector ...

Related keywords