Specifications of DEMOBOARD TLE8201R

Main Purpose
Power Management, High & Low Side Driver (Internal FET)
Embedded
No
Utilized Ic / Part
TLE8201
Primary Attributes
1 H-Bridge @ 3A, 4 Half Bridges- 2 @ 1A, 2 @ 0.5A, 5 High Side 1@ 2.5A, 4 @ 0..5A
Secondary Attributes
SPI Interface, Intended for Automotive Door
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
DEMOBOARDTLE8201RIN
4.4
4.4.1
4.4.1.1
The low-side switches are protected against short circuit to supply and the high-side
switches against short to GND.
If a switch is turned on and the current rises above the shutdown threshold
than the shutdown delay time
corresponding diagnosis bit is set. During the delay time, the current is limited to
shown in
Figure 9
The delay time ia relatively short (typ. 25 µs) to limit the energy that is dissipated in the
device during a short circuit. This scheme allows high peak-currents as required in
motor-applications.
The output stage stays off and the error bit set until a status register reset is sent to the
SPI or a power-on reset is performed.
4.4.1.2
If for instance HS1 is ON and LS1 is OFF, you can turn OFF HS1 and turn ON LS1 with
the same SPI command. To ensure that there is no overlap of the switching slopes that
would lead to a cross current, the dead-time H to L and L to H is specified.
In the control registers, it is also possible to turn ON high- and low-side switches of the
same half-bridge (e.g. LS1ON = H and HS1ON = H). To prevent a cross-current through
the bridge, such a command is not executed. Instead, both switches are turned OFF and
the Over-Load bit is set High for both switches (e.g. LS1OvL = H and HS1OvL = H).
Data Sheet Rev. 2.0
OUTx
Figure
Power-Outputs 1-6 (Bridge Outputs)
Protection and Diagnosis
Short Circuit of Output to Ground or Vs
Cross-Current
short to Vs
short to GND
Short circuit protection
9.
I
O UT
t
dSD
, the output transistor is turned off and the
I
I
SD
SC
25
t
dSD
I
TLE 8201R
SD
2006-06-07
for longer
t
I
SC
as

Related parts for DEMOBOARD TLE8201R