SI3056SSI1-EVB Silicon Laboratories Inc, SI3056SSI1-EVB Datasheet - Page 49

no-image

SI3056SSI1-EVB

Manufacturer Part Number
SI3056SSI1-EVB
Description
BOARD EVAL SI3056/SI3019 SSI
Manufacturer
Silicon Laboratories Inc
Datasheets

Specifications of SI3056SSI1-EVB

Main Purpose
Telecom, Data Acquisition Arrangement (DAA)
Utilized Ic / Part
Si3056
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Secondary Attributes
-
Embedded
-
Primary Attributes
-
Lead Free Status / Rohs Status
Supplier Unconfirmed
Register 1. Control 1
Reset settings = 0000_0000
Bit
5:4
Name
Type
7
6
3
2
1
0
Bit
PWMM[1:0] Pulse Width Modulation Mode.
Reserved
Reserved
PWME
Name
IDL
SR
SB
R/W
SR
D7
Software Reset.
0 = Enables the DAA for normal operation.
1 = Sets all registers to their reset value.
Note: Bit automatically clears after being set.
Read returns zero.
Used to select the type of signal output on the call progress AOUT pin.
00 = PWM output is clocked at 16.384 MHz as a delta-sigma data stream. A local density of
1s and 0s tracks the combined transmit and receive signals.
01 = Balanced conventional PWM output signal has high and low portions of the modulated
pulse that are centered on the 16 kHz sample clock.
10 = Conventional PWM output signal returns to logic 0 at regular 32 kHz intervals and rises
at a time in the 32 kHz period proportional to its instantaneous amplitude.
11 = Reserved.
Pulse Width Modulation Enable.
Sums the transmit and receive audio paths and presents it as a CMOS digital-level output of
PWM data. Use the circuit in “Figure 18. AOUT PWM Circuit for Call Progress” .
0 = Pulse width modulation signal for AOUT disabled.
1 = Pulse width modulation signal for call progress analog output (AOUT) enabled.
Read returns zero.
Isolation Digital Loopback.
0 = Digital loopback across the isolation barrier is disabled.
1 = Enables digital loopback mode across the isolation barrier. The line-side device must be
enabled and off hook before setting this mode. This data path includes the TX and RX filters.
Serial Digital Interface Mode.
0 = Operation is in 15-bit mode, and the LSB of the data field indicates that a secondary
frame is required.
1 = The serial port is operating in 16-bit mode and requires a secondary frame sync signal,
FC, to initiate control data reads/writes.
D6
D5
PWMM[1:0]
R/W
D4
PWME
R/W
D3
Rev. 1.05
D2
Function
R/W
IDL
D1
R/W
SB
D0
Si3018/19/10
49