SI3056SSI1-EVB Silicon Laboratories Inc, SI3056SSI1-EVB Datasheet - Page 54

no-image

SI3056SSI1-EVB

Manufacturer Part Number
SI3056SSI1-EVB
Description
BOARD EVAL SI3056/SI3019 SSI
Manufacturer
Silicon Laboratories Inc
Datasheets

Specifications of SI3056SSI1-EVB

Main Purpose
Telecom, Data Acquisition Arrangement (DAA)
Utilized Ic / Part
Si3056
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Secondary Attributes
-
Embedded
-
Primary Attributes
-
Lead Free Status / Rohs Status
Supplier Unconfirmed
Si3018/19/10
Register 6. DAA Control 2
Reset settings = 0001_0000
Register 7. Sample Rate Control
Reset settings = 0000_0000
54
Bit
7:4
3:0
Name
Name
Type
Type
7:5
2:0
Bit
Bit
4
3
Bit
Reserved Read returns zero.
SRC[3:0]
Name
Reserved Read returns zero.
Reserved Read returns zero.
Name
PDN
PDL
D7
D7
Sample Rate Control.
Sets the sample rate of the line-side device.
0000 = 7200 Hz
0001 = 8000 Hz
0010 = 8229 Hz
0011 = 8400 Hz
0100 = 9000 Hz
0101 = 9600 Hz
0110 = 10286 Hz
0111 = 12000 Hz
1000 = 13714 Hz
1001 = 16000 Hz
1010–1111 = Reserved
Powerdown Line-Side Device.
0 = Normal operation. Program the clock generator before clearing this bit.
1 = Places the line-side device in lower power mode.
Powerdown System-Side Device.
0 = Normal operation.
1 = Powers down the system-side device. A pulse on RESET is required to restore normal
operation.
D6
D6
D5
D5
PDL
R/W
D4
D4
PDN
R/W
D3
D3
Rev. 1.05
D2
D2
SRC[3:0]
Function
Function
R/W
D1
D1
D0
D0

Related parts for SI3056SSI1-EVB