SI3056SSI1-EVB Silicon Laboratories Inc, SI3056SSI1-EVB Datasheet - Page 76

no-image

SI3056SSI1-EVB

Manufacturer Part Number
SI3056SSI1-EVB
Description
BOARD EVAL SI3056/SI3019 SSI
Manufacturer
Silicon Laboratories Inc
Datasheets

Specifications of SI3056SSI1-EVB

Main Purpose
Telecom, Data Acquisition Arrangement (DAA)
Utilized Ic / Part
Si3056
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Secondary Attributes
-
Embedded
-
Primary Attributes
-
Lead Free Status / Rohs Status
Supplier Unconfirmed
Si3018/19/10
Register 41. RX Gain Control 3 (Si3019 Line-Side Device Only)
Reset settings = 0000_0000
Register 42. Reserved
Reset settings = 0000_0000
76
Bit
7:5
3:0
Bit
7:0
Name
Name
Type
4
Type
Bit
Bit
RXG3[3:0] Receive Gain 3.
Reserved Read returns zero.
Reserved Read returns zero.
Name
RGA3
Name
D7
D7
Receive Gain or Attenuation 2.
0 = Incrementing the RXG3[3:0] bits results in gaining up the receive path.
1 = Incrementing the RXG3[3:0] bits results in attenuating the receive path.
Each bit increment represents 0.1 dB of gain or attenuation, up to a maximum of 1.5 dB.
For example:
RGA3
X
0
0
0
1
1
1
D6
D6
D5
D5
RXG3[3:0]
0000
0001
1111
0001
1111
:
:
RGA3
R/W
D4
D4
D3
D3
Rev. 1.05
Result
0 dB gain or attenuation is applied to the receive path.
0.1 dB gain is applied to the receive path.
1.5 dB gain is applied to the receive path.
0.1 dB attenuation is applied to the receive path.
1.5 dB attenuation is applied to the receive path.
D2
D2
RXG3[3:0]
Function
Function
R/W
D1
D1
D0
D0

Related parts for SI3056SSI1-EVB