MAX11068EVKIT+ Maxim Integrated Products, MAX11068EVKIT+ Datasheet - Page 80

no-image

MAX11068EVKIT+

Manufacturer Part Number
MAX11068EVKIT+
Description
KIT SMART BATT MEASUREMENT 12CH
Manufacturer
Maxim Integrated Products
Datasheets

Specifications of MAX11068EVKIT+

Main Purpose
Power Management, Battery Monitor, Car
Utilized Ic / Part
MAX11068
Primary Attributes
Monitors Current, Voltage, Temperature
Secondary Attributes
1 ~ 12 Cell- Li-Ion, 1 ~ 12 Cell- NiMH
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Embedded
-
12-Channel, High-Voltage Sensor, Smart
Data-Acquisition Interface
Table 40. Failure-Mode Effects Analysis (continued)
80
PIN
21
22
23
24
25
26
27
28
29
30
AUXIN1
NAME
AGND
VAA
REF
C0
C1
C2
C3
C4
C5
Open or
disconnected
Short to
pin 22
Open or
disconnected
Short to
pin 23
Open or
disconnected
Short to
pin 24
Open or
disconnected
Short to
pin 25
Open or
disconnected
Short to
pin 26
Open or
disconnected
Short to
pin 27
Open or
disconnected
Short to
pin 28
Open or
disconnected
Short to
pin 29
Open or
disconnected
Short to
pin 30
Open or
disconnected
Short to
pin 31
ACTION
The AIN1 register is around 0.
The result is dependent on the circuit setup of AUXIN1. If REF is driven to VAA, all the
cell input measurements are lower by 1V. If REF is pulled low to AGND, cells 1 to 10
measurement results are all full scale (5V). The DIAG register changes to 0x296 from 0x5D4.
Cells 1 to 12 measurement results vary from 3V to 5V. The DIAG register varies from 0x300
to 0x800. ALRTREF of the FMEA register is set to 1, ALRTFMEA of the STATUS register is
set to 1.
Cell 1 to 12 measurement results are all full scale (5V).
The DIAG register changes to 0x296 from 0x5D4.
No effect.
I
ALRTVDDL of the FMEA register is set to 1. ALRTFMEA of the STATUS register is set to 1.
I
This situation can be detected by the cell sense line open-circuit detection feature.
V
This situation can be detected by the cell sense line open-circuit detection feature.
V
This situation can be detected by the cell sense line open-circuit detection feature.
V
This situation can be detected by the cell sense line open-circuit detection feature.
V
This situation can be detected by the cell sense line open-circuit detection feature.
V
This situation can be detected by the cell sense line open-circuit detection feature.
V
2
2
CELL1
CELL2
CELL3
CELL4
CELL5
CELL6
C lost communication and no heartbeat.
C lost communication and no heartbeat.
= 1V (3V lower).
= 0V.
= 0V.
= 0V.
= 0V.
= 0V.
EFFECT

Related parts for MAX11068EVKIT+