Specifications of CRD4525-Q1

Amplifier Type
Class D
Output Type
2-Channel (Stereo)
Max Output Power X Channels @ Load
15W x 2 @ 8 Ohm
Voltage - Supply
12 V ~ 18 V
Operating Temperature
0°C ~ 70°C
Board Type
Fully Populated
Utilized Ic / Part
CS4525
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Other names
598-1586
92
9.20.8 Mask for Amplifier Error (AmpErrM)
9.21
All bits in this register are considered “level-triggered” events, meaning as long as a condition continues, the corre-
sponding bit will remain set. These status bits are not affected by the interrupt mask bit and the condition of each bit
can be polled. These bits will not be cleared following a read to this register, nor can they be written to cause an
interrupt condition.
9.21.1 SRC State Transition (SRCLockSt)
9.21.2 ADC Overflow (ADCOvflSt)
9.21.3 Sub Overflow (SubOvflSt)
SRCLockSt
7
Interrupt Status (Address 61h) - Read Only
Default = 0
Function:
This bit serves as a mask for the amplifier error interrupt sources. If this bit is set, the AmpErr interrupt is
unmasked, meaning that if the AmpErr bit is set, the INT pin will go active. If the AmpErrM bit is cleared,
the AmpErr condition is masked, meaning that its occurrence will not affect the INT pin. However, the Am-
pErr and the amplifier error bits in the amplifier error status register will continue to reflect the status of the
amplifier error conditions.
Function:
This bit is read only and reflects the current lock state of the SRC. When set, indicates the SRC is currently
locked. When cleared, indicates the SRC is currently unlocked.
Function:
This bit is read only and will identify the presence of an overflow condition within the ADC. When set, in-
dicates that an over-range condition is currently occurring in the CS4525 ADC signal path and has been
clipped to positive or negative full scale.
Function:
This bit is read only and will identify the presence of an overflow condition anywhere in the Sub channel’s
signal path. When set, indicates that an over-range condition is currently occurring in the Sub channel’s
signal path and has been clipped to positive or negative full scale.
AmpErrM Setting
SRCLockSt Setting
ADCOvflSt Setting
SubOvflSt Setting
0 .......................................... AmpErr condition masked.
1 .......................................... AmpErr condition un-masked.
0 .......................................... SRC is currently unlocked.
1 .......................................... SRC is currently locked.
0 .......................................... An ADC overflow condition is not currently present.
1 .......................................... An ADC overflow condition is currently present.
0 .......................................... An overflow condition is not currently present on the Sub channel.
1 .......................................... An overflow condition is currently present on the Sub channel.
ADCOvflSt
6
SubOvflSt
AmpErr INT Pin Mask State
SRC Lock State
ADC Overflow State
Sub Overflow State
5
Ch2OvflSt
4
Ch1OvflSt
3
RampDone
2
Reserved
1
Reserved
CS4525