STEVAL-MKI086V1 STMicroelectronics, STEVAL-MKI086V1 Datasheet - Page 8

BOARD ADAPTER LPY403AL DIL24

STEVAL-MKI086V1

Manufacturer Part Number
STEVAL-MKI086V1
Description
BOARD ADAPTER LPY403AL DIL24
Manufacturer
STMicroelectronics
Series
MEMSr

Specifications of STEVAL-MKI086V1

Sensor Type
Gyroscope, 2 Axis
Sensing Range
±30°/sec
Interface
Analog
Sensitivity
33.3mV/°/s
Voltage - Supply
5V, USB
Embedded
Yes, MCU, 8-Bit
Utilized Ic / Part
LPR403AL
Interface Type
GUI, USB
For Use With
497-10682 - MOTEHRBOARD MEMS ADAPTER STM32
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
For Use With/related Products
LPY403AL
Other names
497-10609
Working modes
2
2.1
8/35
Working modes
The STEVAL-MKI0xxV1 demonstration board is designed to be used in two different
working modes:
Each working mode requires a board setup, which is done by correctly setting the jumpers
labeled JP4, JP5, JP7 (see ref 1, ref 2 and ref 3, respectively, in
labeled JP1 and JP6 (see ref 4 and ref 5, respectively, in
Analog working mode (AWM)
AWM is the working mode activated by default when the board is connected to a PC by USB
or when the power supply is applied to J10. The microcontroller on the board is disabled and
board behavior can be controlled through the dedicated jumpers.
In this working mode, the power down (PD), self-test (ST) and high-pass filter reset (HP)
functions are respectively managed by JP4, JP5 and JP7 as described below (see
to identify the jumpers):
Table 1.
Analog output signals can be measured respectively through pin 3 (marked Out1), pin 4
(marked Out2, for single-axis devices only) and pin1 (GND) of the J3 header (see
ref 7).
The JP1 and JP6 jumpers allow the user to select which output signal is available on J3.
JP4
JP5
JP7
PD
HP
ST
Analog working mode (AWM): the microcontroller on the board is disabled and the
analog outputs of the device are available to the user on the dedicated connector
(Figure
the USB connector or through the supply connector
Digital working mode (DWM): the microcontroller on the board is enabled and allows
the user to digitally acquire the output signals of the device, to see them on the PC
through the dedicated GUI and to manage the control pins of the device.
Logic level 1: external high-pass filter reset
3, ref 7). This is the default working mode when power is applied either through
Jumper configurations for power down (PD), self-test (ST) and high pass
filter reset (HP) in AWM
Logic level 1: power down mode
Logic level 1: self-test ON
Jumper on 1-2 position
Doc ID 16617 Rev 1
Logic level 0: normal mode, default
Logic level 0: normal mode, default
Logic level 0: self-test OFF, default
(Figure
Figure
Jumper on 2-3 position
3).
Figure
3, ref 10).
3) and the jumpers
Figure
Figure 3
UM0855
3,

Related parts for STEVAL-MKI086V1