STEVAL-MKI086V1 STMicroelectronics, STEVAL-MKI086V1 Datasheet - Page 9

BOARD ADAPTER LPY403AL DIL24

STEVAL-MKI086V1

Manufacturer Part Number
STEVAL-MKI086V1
Description
BOARD ADAPTER LPY403AL DIL24
Manufacturer
STMicroelectronics
Series
MEMSr

Specifications of STEVAL-MKI086V1

Sensor Type
Gyroscope, 2 Axis
Sensing Range
±30°/sec
Interface
Analog
Sensitivity
33.3mV/°/s
Voltage - Supply
5V, USB
Embedded
Yes, MCU, 8-Bit
Utilized Ic / Part
LPR403AL
Interface Type
GUI, USB
For Use With
497-10682 - MOTEHRBOARD MEMS ADAPTER STM32
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
For Use With/related Products
LPY403AL
Other names
497-10609
UM0855
Note:
Note:
2.2
Table 2.
Not connected for single axis devices
The JP9 and JP8 (for double axis devices only; see
the management of external (HP and LP) filters, respectively, for Out2 and Out1.
Table 3.
Not connected for single axis devices.
Digital working mode (DWM)
When the board is configured for DWM, it can be controlled by a PC through the dedicated
GUI. The USB works as an interface channel between the PC and demonstration kit board
by means of the microcontroller. The microcontroller takes advantage of its on-board 8-bit
A/D converter to read analog values from the device and to convert them in digital values,
then sends them to the PC via the USB channel.
For the board to work in DWM, the jumpers must be configured as described in
Table 4.
Users can interact with the board by means of the STEVAL-MKI0xxV1 GUI and/or
Microsoft
JP1
JP6
1
©
1xOut1 (not amplified): on J3-pin 3 (Out1)
1xOut2 (not amplified): on J3-pin 4 (Out2)
Hyper Terminal (refer to
Jumper configurations for JP1 and JP6 in AWM
Jumper configurations for JP9 and JP8 in AWM
Jumper configuration for DWM
Configuration
pin 1-2 short
pin 3-4 short
pin 3-4 short
pin 2-4 open
JP1 and JP6
JP9 and JP8
Jumper on 1-2 position
Jumper
JP5 PD
JP7 HP
JP4 ST
Doc ID 16617 Rev 1
Section 4
and
Section
Figure
4xOut1 (amplified): on J3-pin 3 (Out1)
4xOut2 (amplified): on J3-pin 4 (Out2)
HP and LP filters bypassed
2-3 (default) or not connected
2-3 (default) or not connected
2-3 (default) or not connected
HP and LP filters enabled
7).
3, ref 6 and ref 11) jumpers allow
Jumper on 2-3 position
JUMPER position
Refer to
Refer to
Function
Table 1
Table 3
Working modes
Table
4.
9/35

Related parts for STEVAL-MKI086V1