Y92F-30 Omron, Y92F-30 Datasheet - Page 12

ADAPTER PANEL MNT FOR H3CR/H5CX

Y92F-30

Manufacturer Part Number
Y92F-30
Description
ADAPTER PANEL MNT FOR H3CR/H5CX
Manufacturer
Omron
Type
Panel Mounting Adaptersr
Datasheets

Specifications of Y92F-30

Accessory Type
Panel Mount Adapter, Frame
Mounting Type
Panel Mount
Rohs Compliant
Yes
Length
58 mm
Mounting Hole Size
45 mm
For Use With/related Products
Multiple Series
For Use With
Z3000 - RELAY TIMER DGTL SPDT 12-24VDCZ2999 - RELAY TIMER DGTL SPDT 100/240VACZ2998 - RELAY TIMER DGTL SPDT 100/240VACH3CR-A8E AC100-240/DC100-125 - RELAY ANALOG SET DPDT 8PINZ2815 - RELAY REPEAT CYCLE ANALOG 30HRSZ2387 - RELAY TIMER 0-12SEC OFF-DELAYZ2386 - RELAY TIMER 0-12MIN OFF-DELAYZ2385 - RELAY REPEAT CYCLE ANALOG 30HRSZ2384 - RELAY REPEAT CYCLE ANALOG 300HRSZ2381 - RELAY ANALOG SET DPDT 8PINZ2380 - RELAY ANALOG SET DPDT 8PINZ2379 - RELAY ANALOG SET DPDT 8PINZ2366 - RELAY REPEAT CYCLE ANLG 30HRSZ2382 - RELAY REPEAT CYCLE ANLG 30HRSZ997 - RELAY TIMER ANALOG 24VDC/ACZ2358 - RELAY REPEAT CYCLE ANLG 30HRSZ876 - RELAY TIMER DPDT ANALOG 120\240V
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Color
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
Y92F30
Z885
H5CR
The flowchart below shows operation common to all H5CR models. Refer to the Setting Item Table for details on the operation of specific
modes.
Note: 1. Set values are changed using
* Key protection is not included in the H5CR-L.
The following table shows the timer settings when it is shipped. Change the settings as necessary to suit the system before
operation. Settings and the display receive power from the internal battery and are, therefore, unaffected by external power
interruptions. With the initial settings, there will be no output even if the power supply is connected. External inputs and outputs
cannot be used without a power supply.
Model
Time range
Present value
Presets
UP/DOWN mode
Output mode
Output time
Input signal time
Key protect level
Inputs
Outputs
Key name
Increment keys (1-4)
Display key
Mode key
Reset key
KEY OPERATIONS
FACTORY SETTINGS
INPUT/OUTPUT FUNCTIONS
OPERATIONAL OVERVIEW
2. The large arrows indicate the
the increment keys (1 to 4).
parameter displayed first when the mode
is changed with the MODE or DISPLAY key.
Start signal
Reset
Gate
Key protect
Control output (OUT)
Run mode
H5CR-B (Standard)/H5CR-S (Short body)
- -.- -s
0.00 s
0.00 s
UP
A: Signal ON-delay (1)
Hold
20 ms
KP-1
Operation
Used to change the corresponding digit of the set value. Used to change data in the set mode.
Switches to the present value display.
Switches from run mode to set mode. Changes items in the set mode.
Resets timing and outputs.
Present value,
set value
Stops timing in A-2 and A-3 (power ON-delay) modes. Starts timing in other modes.
Resets present value (to zero in UP mode, to preset in DOWN mode).
Control inputs are not accepted while reset input is ON.
Reset indicator lit while reset input is ON.
Inhibits timer operation.
Makes keys inoperative according to key protect level.
Key protected indicator lit while key protect input is ON.
Effective when protect terminals are shorted.
Effective if power supply is turned off.
Outputs made according to designated output mode when corresponding preset is reached.
Press the
MODE key
Press the
DISPLAY key
12
Press the
MODE key
Setting mode
H5CR-L (Economy)
Key protect level *
Input signal time
UP/DOWN mode
Timing range
Output mode
Output time
Press the
MODE key
Press the
MODE key
Press the
MODE key
Press the
MODE key
Press the
MODE key
H5CR