Y92F-30 Omron, Y92F-30 Datasheet - Page 6

ADAPTER PANEL MNT FOR H3CR/H5CX

Y92F-30

Manufacturer Part Number
Y92F-30
Description
ADAPTER PANEL MNT FOR H3CR/H5CX
Manufacturer
Omron
Type
Panel Mounting Adaptersr
Datasheets

Specifications of Y92F-30

Accessory Type
Panel Mount Adapter, Frame
Mounting Type
Panel Mount
Rohs Compliant
Yes
Length
58 mm
Mounting Hole Size
45 mm
For Use With/related Products
Multiple Series
For Use With
Z3000 - RELAY TIMER DGTL SPDT 12-24VDCZ2999 - RELAY TIMER DGTL SPDT 100/240VACZ2998 - RELAY TIMER DGTL SPDT 100/240VACH3CR-A8E AC100-240/DC100-125 - RELAY ANALOG SET DPDT 8PINZ2815 - RELAY REPEAT CYCLE ANALOG 30HRSZ2387 - RELAY TIMER 0-12SEC OFF-DELAYZ2386 - RELAY TIMER 0-12MIN OFF-DELAYZ2385 - RELAY REPEAT CYCLE ANALOG 30HRSZ2384 - RELAY REPEAT CYCLE ANALOG 300HRSZ2381 - RELAY ANALOG SET DPDT 8PINZ2380 - RELAY ANALOG SET DPDT 8PINZ2379 - RELAY ANALOG SET DPDT 8PINZ2366 - RELAY REPEAT CYCLE ANLG 30HRSZ2382 - RELAY REPEAT CYCLE ANLG 30HRSZ997 - RELAY TIMER ANALOG 24VDC/ACZ2358 - RELAY REPEAT CYCLE ANLG 30HRSZ876 - RELAY TIMER DPDT ANALOG 120\240V
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Color
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
Y92F30
Z885
1 2 3
1 2 3
1 2 3
1 2 3
1 2 3
H5CR
The gate input is not included in the H5CR-L .
Note: A twin timer can be created by using one of the repeat modes. For example, if the set value is 60 s and the one shot time is 10 s
Timing
diagram
Timing
diagram
Timing
diagram
Output mode D : Signal OFF delay (Timer resets when power comes ON.)
Output mode E: Interval (Timer resets when power comes ON.)
Output mode F: Cumulative (Timer does not reset when power comes ON.)
One-shot
in repeat mode, the control output will turn OFF for 50 s and ON for 10 s. (In the first cycle, however, the control output will turn
OFF for 60 s.) In this way, the work of two timers can be performed by a single timer.
Sustained output
DOWN
DOWN
DOWN
UP
UP
UP
Control output
Control output
Control output
10 s
Start signal
Set value
Set value
Start signal
Start signal
Set value
Set value
Set value
Set value
Power
Reset
Power
Power
Gate
Reset
Reset
Gate
Gate
0
0
0
0
0
0
60 s
50 s
One-shot outputs can be set to 0.1 s, 0.5 s, 1 s, 5 s, 10 s, 20 s.
6
** Start signal input is enabled during timing.
** Start signal input is disabled during timing.
The timer is reset when the time is up.
* Output functions only during start signal input when
Start signal enables timing (timing is stopped when the
start signal is OFF or when the power is OFF).
A sustained control output is used.
* Output is instantaneous when setting is 0.
The control output is ON when the start signal is
ON (except when the power is OFF or the reset is
ON).
Start signal
input
* Output is disabled when the setting is 0.
Timing starts when the start signal comes ON.
The control output is reset when time is up.
While the start signal is ON, the timer starts when
power comes ON or when the reset input goes OFF.
Start signal
input
Start signal
input
Basic Operation
setting is 0.
Basic Operation
Basic Operation
Output
Power
Output
Power
Output
Power
**
**
Timing
Timing
Sustained
Timing
Timing
H5CR