G7SA-3A1B-DC24 Omron, G7SA-3A1B-DC24 Datasheet - Page 2

RELAY SAFETY PCB 3PST-NO/1NC 24V

G7SA-3A1B-DC24

Manufacturer Part Number
G7SA-3A1B-DC24
Description
RELAY SAFETY PCB 3PST-NO/1NC 24V
Manufacturer
Omron
Series
G7SAr
Datasheets

Specifications of G7SA-3A1B-DC24

Relay Type
Safety
Contact Form
4PST (3 Form A, 1 Form B)
Contact Rating (current)
6A
Switching Voltage
250VAC, 125VDC - Max
Coil Type
Standard
Coil Current
20.8mA
Coil Voltage
24VDC
Turn On Voltage (max)
18 VDC
Turn Off Voltage (min)
2.4 VDC
Mounting Type
Socket
Termination Style
Socketable
Circuit
4PST (3 Form A, 1 Form B)
Contact Rating @ Voltage
6A @ 30VDC
Control On Voltage (max)
18 VDC
Control Off Voltage (min)
2.4 VDC
Contact Rating
6 A
Contact Termination
Pin
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant
Other names
G7SA3A1BDC24
Z2943
Specifications
Contacts
■ Characteristics
Sockets
Note: 1. If the P7SA-1@F is used between 55 and 85 C, reduce the continuous current (from 6 A) by 0.1 A for every degree.
Relays with Forcibly Guided Contacts
Note: 1. The values listed above are initial values.
G-4
Load
Rated load
Rated carry current
Max. switching voltage
Max. switching current
P7SA-14@
Contact resistance (See note 2.)
Operating time (See note 3.)
Response time (See note 4.)
Release time (See note 3.)
Maximum
operating
frequency
Insulation resistance
(See note 5.)
Dielectric strength
(see notes 6, 7)
Vibration resistance
Shock resistance
Durability
(see note 8)
Failure rate (P level) (see note 9)
(reference value)
Ambient temperature (see note 10) Operating: 40 C to 85 C (with no icing or condensation)
Ambient humidity
Weight
2. Measurement conditions: Measurement of the same points as for the dielectric strength at 500 VDC.
3. When using the P7SA-1@F-ND at 24 VDC, use at an ambient operating temperature from 25 to 55 C.
2. The contact resistance was measured with 1 A at 5 VDC using the voltage-drop method.
3. These times were measured at the rated voltage and an ambient temperature of 23 C. Contact bounce time is included.
4. The response time is the time it takes for the normally open contacts to open after the coil voltage is turned OFF. Contact bounce time is
5. The insulation resistance was measured with a 500-VDC megohmmeter at the same locations as the dielectric strength was measured.
6. Pole 3 refers to terminals 31 32 or 33 34, pole 4 refers to terminals 43 44, pole 5 refers to terminals 53 54, and pole 6 refers to terminals
7. When using a P7SA Socket, the dielectric strength between coil contacts/different poles is 2,500 VAC, 50/60 Hz for 1 min.
8. The durability is for an ambient temperature of 15 C to 35 C and an ambient humidity of 25% to 75%.
9. The failure rate is based on an operating frequency of 300 operations/min.
10.When operating at a temperature between 70 C and 85 C, reduce the rated carry current (6 A at 70 C or less) by 0.1 A for each degree
Model
included. Measurement conditions: Rated voltage operation, Ambient temperature: 23 C
63 64.
above 70 C.
Relays with Forcibly Guided Contacts
6 A (See note 1.)
Mechanical
Rated load
Destruction
Malfunction
Mechanical
Electrical
Continuous current
100 m
20 ms max.
10 ms max.
20 ms max.
36,000 operations/hr
1,800 operations/hr
1,000 M
Between coil contacts/different poles (except for poles 3 4 in 4-pole Relays and poles 3 5, 4 6, and 5 6
in 6-pole Relays): 4,000 VAC, 50/60 Hz for 1 min.
Between between poles 3 4 in 4-pole Relays and poles 3 5, 4 6, and 5 6 in 6-pole Relays:
2,500 VAC, 50/60 Hz for 1 min.
Between contacts of same polarity: 1,500 VAC, 50/60 Hz for 1 min.
10 to 55 Hz, 0.75-mm single amplitude (1.5-mm double amplitude)
1,000 m/s
100 m/s
10,000,000 operations min. (at approx. 36,000 operations/hr)
100,000 operations min. (at the rated load and approx. 1,800 operations/hr)
5 VDC, 1 mA
Operating: 5% to 85%RH
4 poles:
6 poles:
2
max.
6 A at 250 VAC, 6 A at 30 VDC
6 A
250 VAC, 125 VDC
6 A
2
min. (at 500 VDC)
Approx. 22 g
Approx. 25 g
2,500 VAC for 1 min. between poles
Resistive load
G7SA
Dielectric strength
1,000 M
min. (See note 2.)
Insulation resistance

Related parts for G7SA-3A1B-DC24