H3CR-A AC24-48/DC12-48 Omron, H3CR-A AC24-48/DC12-48 Datasheet - Page 12

RELAY TIMER ANALOG 24VDC/AC

H3CR-A AC24-48/DC12-48

Manufacturer Part Number
H3CR-A AC24-48/DC12-48
Description
RELAY TIMER ANALOG 24VDC/AC
Manufacturer
Omron
Series
H3CR-Ar

Specifications of H3CR-A AC24-48/DC12-48

Mounting Type
Socket
Relay Type
Integrated
Function
Programmable (Multi-Function)
Circuit
DPDT (2 Form C)
Delay Time
0.05 Sec ~ 300 Hrs
Output Type
Mechanical Relay
Contact Rating @ Voltage
5A @ 240VAC
Voltage - Supply
24 ~ 48VAC, 12 ~ 48VDC
Termination Style
11 Pin Socketable
Timing Adjustment Method
Hand Dial
Timing Initiate Method
Input Voltage
Time Range
0.05 Sec. To 300 Hr.
Supply Voltage Ac, Min
24VAC
No. Of Timing Functions
6
Body Material
93B4352
No. Of Pins
11
Supply Voltage Ac, Max
48VAC
Load Current Rms Max
5A
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
H3CR-A-AC/DC24
H3CRAAC24-48/DC12-48
H3CRAAC2448DC1248
Z997
Gate Signal Input
D:
Signal OFF-
delay
E:
Interval
G:
Signal ON/
OFF-delay
J:
One-shot
output
Operating
Output
relay
Power
Reset
Gate
mode
Start
Note: 1. This timing chart indicates the gate input in
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
2. The set time is the sum of t
3. H3CR-AP model incorporates start input only.
Output relay (NC)
Output relay (NO)
(Output indicator)
Output relay (NO)
(Output indicator)
Output relay (NC)
Output relay (NO)
(Output indicator)
Output relay (NC)
Output relay (NO)
(Output indicator)
Output relay (NC)
operating mode A (ON-delay operation).
Power indicator
Power indicator
Power indicator
Power indicator
t
1
Power
Power
Power
Power
Reset
Reset
Reset
Reset
Start
Start
Start
Start
t
2
1±0.6 s
(Fixed)
1
and t
2.
1±0.6 s
(Fixed)
Timing chart
(See note)
Output
Basic operation
Power
Start
Note: Start input is valid and
(See note)
Output
Basic operation
Power
Start
Note: Start input is valid and
(See note)
retriggerable while the Timer
is in operation.
t
Basic operation
Output
Note: Start input is valid and
Power
Start
Note: Start input is valid and
(See note)
retriggerable while the
Timer is in operation.
t
Basic operation
Output
Power
Start
t
retriggerable while the
Timer is in operation.
retriggerable while the
Timer is in operation.
t
t
1±0.6 s
(Fixed)
t
t
H3CR-A
12