H3DE-M2 DC12 Omron, H3DE-M2 DC12 Datasheet - Page 9

no-image

H3DE-M2 DC12

Manufacturer Part Number
H3DE-M2 DC12
Description
RELAY TIMER ANALOG DIN 8MODE 12V
Manufacturer
Omron
Series
H3DEr
Datasheet

Specifications of H3DE-M2 DC12

Relay Type
Integrated
Function
Programmable (Multi-Function)
Circuit
DPDT (2 Form C)
Delay Time
0.1 Sec ~ 120 Hrs
Output Type
Mechanical Relay
Contact Rating @ Voltage
5A @ 250VAC
Voltage - Supply
12VDC
Mounting Type
DIN Rail
Termination Style
Screw Terminal
Timing Adjustment Method
Screwdriver Slot
Timing Initiate Method
Input Voltage
Lead Free Status / RoHS Status
Contains lead / RoHS compliant by exemption
Other names
H3DEM2DC12
Q2295545
Q2734960
Timing Chart —
Note: The start input of the H3DE-M1 or H3DE-M2 model is activated by applying a voltage to B1 and A2 terminals.
Operating
mode
D:
Signal
OFF-delay
E: Interval
G:
Signal
ON/OFF-
delay
J:
One-shot
output
(ON delay)
The voltage can be applied by turning on the contact between B1 and A1 (Refer to Terminal Arrangement).
Timing chart
Output relay: NC
15 and 16
(25 and 26)
Output relay: NO
(output indicator)
15 and 18
(25 and 28)
Power (A
Start (B
(See Note.)
Output relay: NC
15 and 16
(25 and 26)
Output relay: NO
(output indicator)
15 and 18
(25 and 28)
Power indicator
Power (A
Start (B
(See Note.)
Output relay: NC
15 and 16
(25 and 26)
Output relay: NO
(output indicator)
15 and 18
(25 and 28)
Power indicator
Power (A
Start (B
(See Note.)
Output relay: NC
15 and 16
(25 and 26)
Output relay: NO
(output indicator)
15 and 18
(25 and 28)
Power indicator
Power (A
Start (B
(See Note.)
Power indicator
continued from previous page
1
1
1
1
1
and A
1
and A
1
and A
1
and A
and A
and A
and A
and A
2
2
2
2
)
)
)
)
2
2
2
2
)
)
)
)
Approx.
1±0.6 s
(fixed)
t
t
t t
Approx.
1±0.6 s
(fixed)
t
t
t- -a
t- -a
t- -a
t- -a
t- -a
Approx.
1±0.6 s
(fixed)
t- -a
t
t
t
t- -a
Output
Output
Power
Power
Output
Power
Start
Basic operation
*
Start
Output
Power
Start
*
Start
*
** Start input is valid and re-triggerable while the
*
*
** Start input is valid and re-triggerable while the
Basic operation
Basic operation
Basic operation
*
Start input is valid and re-triggerable while the
Timer is in operation.
For power-on operation, impose voltage to the
Start input is valid and re-triggerable while the
For power-on operation, impose voltage to the
Start input. The Timer starts operating at the
moment the power is turned on.
Timer is in operation.
Timer is in operation.
Start input. The Timer starts operating at the
moment the power is turned on.
Timer is in operation.
**
**
t
*
*
t
t
t
t
Approx. 1±0.6 s
(fixed)
t
t

Related parts for H3DE-M2 DC12