H5CX-A AC100-240 Omron, H5CX-A AC100-240 Datasheet - Page 49

RELAY TIMER DIGITAL SPDT 100/240

H5CX-A AC100-240

Manufacturer Part Number
H5CX-A AC100-240
Description
RELAY TIMER DIGITAL SPDT 100/240
Manufacturer
Omron
Series
H5CXr
Datasheets

Specifications of H5CX-A AC100-240

Relay Type
Integrated
Function
Programmable (Multi-Function)
Circuit
SPDT (1 Form C)
Delay Time
0.001 Sec ~ 9999 Hrs
Output Type
Mechanical Relay
Contact Rating @ Voltage
5A @ 250VAC
Voltage - Supply
100 ~ 240VAC
Mounting Type
Panel Mount
Termination Style
Screw Terminal
Timing Adjustment Method
DIP Switches
Timing Initiate Method
Input Voltage, Trigger Signal
Lead Free Status / RoHS Status
Contains lead / RoHS compliant by exemption
Other names
H5CX-A-AC100-240
H5CXAAC100240
Z1645
Safety Precautions (H5CX-A/-L)
If the output relay is used beyond its life expectancy, its contacts
may occasionally become fused or there may occasionally be a risk
of fire. The life expectancy of the output relay varies considerably
according to its usage. Use the output relay within its rated load and
electrical life expectancy.
Depending on the wiring, unwanted current from the AC power
supply may occasionally burn out (damage) the internal parts.
The H5CX-A/-L (except for H5CX-A11/-A11S) do not have
transformers. Therefore, there is no insulation between the power
supply and input terminals, so make sure that wiring is correct before
use.
For the power supply of an input device of the H5CX (except for
H5CX-A11/-A11S), use an isolating transformer with the primary and
secondary windings mutually isolated and the secondary winding not
grounded.
Correct Wiring Example
Incorrect Wiring Example 1
Do not ground the secondary winding. If the secondary wiring is
grounded, as shown in the following diagram, unwanted current may
occasionally burn out or damage the internal parts.
Incorrect Wiring Example 2
Do not simultaneously input signals from a single input contact or a
transistor to two or more timers that have independent power
supplies. Otherwise, the internal parts may occasionally be burnt out
or damaged by unwanted current, as shown in the following diagram.
Circuit
Circuit
Input
terminals
H5CX
Input
terminals
Input
terminals
Input
terminals
H5CX
H5CX
Isolation transformer is required.
Power supply
CAUTION
Power supply
Power supply
■ Precautions for Safe Use
Usage Precautions
Do not touch the input terminals while power is supplied. The H5CX
(except for H5CX-A11/-A11S) has a transformerless power supply
and so touching the input terminals with power supplied may result in
electric shock.
Changing the Set Values
When changing the set value during a timing operation, the output
will turn ON if the set value is changed as follows because of the use
of a constant read-in system:
Elapsed time (UP) mode: Present value ≥ set value
Remaining time (DOWN) mode: Elapsed time ≥ set value
Note: When in the remaining time mode, the amount the set value is
■ Precautions for Correct Use
Operation with a Set Value of 0
Operation with a set value of 0 will vary with the output mode. Refer
to the Timing Charts.
changed is added to or subtracted from the present value.
(The present value is set to 0.)
H5CX-B
49