ATTINY26-16PU Atmel, ATTINY26-16PU Datasheet - Page 35

IC AVR MCU 2K 16MHZ IND 20-DIP

ATTINY26-16PU

Manufacturer Part Number
ATTINY26-16PU
Description
IC AVR MCU 2K 16MHZ IND 20-DIP
Manufacturer
Atmel
Series
AVR® ATtinyr
Datasheets

Specifications of ATTINY26-16PU

Core Processor
AVR
Core Size
8-Bit
Speed
16MHz
Connectivity
USI
Peripherals
Brown-out Detect/Reset, POR, PWM, WDT
Number Of I /o
16
Program Memory Size
2KB (1K x 16)
Program Memory Type
FLASH
Eeprom Size
128 x 8
Ram Size
128 x 8
Voltage - Supply (vcc/vdd)
4.5 V ~ 5.5 V
Data Converters
A/D 11x10b
Oscillator Type
Internal
Operating Temperature
-40°C ~ 85°C
Package / Case
20-DIP (0.300", 7.62mm)
Processor Series
ATTINY2x
Core
AVR8
Data Bus Width
8 bit
Data Ram Size
128 B
Interface Type
2-Wire/ISP/SM-Bus/SPI/UART/USI
Maximum Clock Frequency
16 MHz
Number Of Programmable I/os
16
Number Of Timers
2
Operating Supply Voltage
4.5 V to 5.5 V
Maximum Operating Temperature
+ 85 C
Mounting Style
Through Hole
3rd Party Development Tools
EWAVR, EWAVR-BL
Development Tools By Supplier
ATAVRDRAGON, ATSTK500, ATSTK600, ATAVRISP2, ATAVRONEKIT
Minimum Operating Temperature
- 40 C
On-chip Adc
11-ch x 10-bit
Package
20PDIP
Device Core
AVR
Family Name
ATtiny
Maximum Speed
16 MHz
For Use With
ATSTK600 - DEV KIT FOR AVR/AVR32770-1007 - ISP 4PORT ATMEL AVR MCU SPI/JTAGATAVRISP2 - PROGRAMMER AVR IN SYSTEMATSTK505 - ADAPTER KIT FOR 14PIN AVR MCU
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Brown-out
Detection
Watchdog Reset
1477K–AVR–08/10
ATtiny26(L) has an On-chip Brown-out Detection (BOD) circuit for monitoring the V
ing the operation. The BOD circuit can be enabled/disabled by the fuse BODEN. When the BOD
is enabled (BODEN programmed), and V
Reset is immediately activated. When V
Reset is deactivated after a delay. The delay is defined by the user in the same way as the delay
of POR signal, in Table 29. The trigger level for the BOD can be selected by the fuse
BODLEVEL to be 2.7V (BODLEVEL unprogrammed), or 4.0V (BODLEVEL programmed). The
trigger level has a hysteresis of 50 mV to ensure spike free Brown-out Detection.
The BOD circuit will only detect a drop in V
ger than t
Figure 29. Brown-out Reset During Operation
When the Watchdog times out, it will generate a short reset pulse of one CK cycle duration. On
the falling edge of this pulse, the delay timer starts counting the Time-out period t
page 78 for details on operation of the Watchdog.
Figure 30. Watchdog Time-out
INTERNAL
TIME-OUT
RESET
RESET
BOD
V
CC
given in Table 16.
V
BOT-
1 CK Cycle
CC
CC
CC
increases above the trigger level, the Brown-out
decreases below the trigger level, the Brown-out
if the voltage stays below the trigger level for lon-
V
t
TOUT
BOT+
TOUT
CC
. Refer to
level dur-
35

Related parts for ATTINY26-16PU