MC68HC908SR12CB Freescale Semiconductor, MC68HC908SR12CB Datasheet - Page 286

no-image

MC68HC908SR12CB

Manufacturer Part Number
MC68HC908SR12CB
Description
IC MCU 12K FLASH 8MHZ 42-SDIP
Manufacturer
Freescale Semiconductor
Series
HC08r
Datasheet

Specifications of MC68HC908SR12CB

Core Processor
HC08
Core Size
8-Bit
Speed
8MHz
Connectivity
I²C, SCI
Peripherals
LVD, POR, PWM, Temp Sensor
Number Of I /o
29
Program Memory Size
12KB (12K x 8)
Program Memory Type
FLASH
Ram Size
512 x 8
Voltage - Supply (vcc/vdd)
2.7 V ~ 5.5 V
Data Converters
A/D 11x10b
Oscillator Type
Internal
Operating Temperature
-40°C ~ 85°C
Package / Case
42-DIP (0.600", 15.24mm)
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Eeprom Size
-

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
MC68HC908SR12CB
Manufacturer:
TI/NSC
Quantity:
340
Part Number:
MC68HC908SR12CB
Manufacturer:
MOT
Quantity:
2 313
Part Number:
MC68HC908SR12CB
Manufacturer:
MOTOROLA/摩托罗拉
Quantity:
20 000
Company:
Part Number:
MC68HC908SR12CB
Quantity:
1
Company:
Part Number:
MC68HC908SR12CB
Quantity:
7 840
Serial Communications Interface (SCI)
16.9.5 SCI Status Register 2
Data Sheet
286
Address:
SCI status register 2 contains flags to signal the following conditions:
BKF — Break Flag Bit
RPF — Reception in Progress Flag Bit
Reset:
Read:
Write:
This clearable, read-only bit is set when the SCI detects a break
character on the RxD pin. In SCS1, the FE and SCRF bits are also
set. In 9-bit character transmissions, the R8 bit in SCC3 is cleared.
BKF does not generate a CPU interrupt request. Clear BKF by
reading SCS2 with BKF set and then reading the SCDR. Once
cleared, BKF can become set again only after logic 1s again appear
on the RxD pin followed by another break character. Reset clears the
BKF bit.
This read-only bit is set when the receiver detects a logic 0 during the
RT1 time period of the start bit search. RPF does not generate an
interrupt request. RPF is reset after the receiver detects false start bits
(usually from noise or a baud rate mismatch) or when the receiver
detects an idle character. Polling RPF before disabling the SCI
module or entering stop mode can show whether a reception is in
progress.
1 = Break character detected
0 = No break character detected
1 = Reception in progress
0 = No reception in progress
Break character detected
Incoming data
Serial Communications Interface (SCI)
$0017
Bit 7
0
Figure 16-14. SCI Status Register 2 (SCS2)
= Unimplemented
6
0
5
0
MC68HC908SR12•MC68HC08SR12 — Rev. 5.0
4
0
3
0
Freescale Semiconductor
2
0
BKF
1
0
Bit 0
RPF
0