XC705B32CFNE Freescale Semiconductor, XC705B32CFNE Datasheet - Page 129

no-image

XC705B32CFNE

Manufacturer Part Number
XC705B32CFNE
Description
IC MCU 2.1MHZ 32K OTP 52-PLCC
Manufacturer
Freescale Semiconductor
Series
HC05r
Datasheet

Specifications of XC705B32CFNE

Core Processor
HC05
Core Size
8-Bit
Speed
2.1MHz
Connectivity
SCI
Peripherals
POR, WDT
Number Of I /o
32
Program Memory Size
32KB (32K x 8)
Program Memory Type
OTP
Eeprom Size
256 x 8
Ram Size
528 x 8
Voltage - Supply (vcc/vdd)
4.5 V ~ 5.5 V
Data Converters
A/D 8x8b; D/A 2x8b
Oscillator Type
Internal
Operating Temperature
-40°C ~ 85°C
Package / Case
52-PLCC
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
XC705B32CFNE
Manufacturer:
SILICON
Quantity:
101
Part Number:
XC705B32CFNE
Manufacturer:
Freescale Semiconductor
Quantity:
10 000
10.3.8
The relative addressing mode is only used in branch instructions. In relative addressing, the
contents of the 8-bit signed byte (the offset) following the opcode are added to the PC if, and only
if, the branch conditions are true. Otherwise, control proceeds to the next instruction. The span of
relative addressing is from –126 to +129 from the opcode address. The programmer need not
calculate the offset when using the Freescale assembler, since it calculates the proper offset and
checks to see that it is within the span of the branch.
10.3.9
In the bit set/clear addressing mode, the bit to be set or cleared is part of the opcode. The byte
following the opcode specifies the address of the byte in which the specified bit is to be set or
cleared. Any read/write bit in the first 256 locations of memory, including I/O, can be selectively set
or cleared with a single two-byte instruction.
10.3.10
The bit test and branch addressing mode is a combination of direct addressing and relative
addressing. The bit to be tested and its condition (set or clear) is included in the opcode. The
address of the byte to be tested is in the single byte immediately following the opcode byte (EA1).
The signed relative 8-bit offset in the third byte (EA2) is added to the PC if the specified bit is set
or cleared in the specified memory location. This single three-byte instruction allows the program
to branch based on the condition of any readable bit in the first 256 locations of memory. The span
of branch is from –125 to +130 from the opcode address. The state of the tested bit is also
transferred to the carry bit of the condition code register.
MC68HC05B6
Rev. 4.1
Relative
Bit set/clear
Bit test and branch
Address bus high ← 0; Address bus low ← (PC+1)
Address bus high ← 0; Address bus low ← (PC+1)
EA2 = PC+3+(PC+2); PC ← EA2 if branch taken;
EA = PC+2+(PC+1); PC ← EA if branch taken;
CPU CORE AND INSTRUCTION SET
otherwise EA = PC ← PC+2
EA1 = (PC+1); PC ← PC+2
EA = (PC+1); PC ← PC+2
otherwise PC ← PC+3
Freescale
10-13
10