MAX6877ETG+ Maxim Integrated Products, MAX6877ETG+ Datasheet - Page 13

IC SEQUENCE/SUPERVISOR 24TQFN

MAX6877ETG+

Manufacturer Part Number
MAX6877ETG+
Description
IC SEQUENCE/SUPERVISOR 24TQFN
Manufacturer
Maxim Integrated Products
Type
Sequencerr
Datasheet

Specifications of MAX6877ETG+

Number Of Voltages Monitored
3
Output
Open Drain or Open Collector
Reset
Active Low
Reset Timeout
Adjustable/Selectable
Voltage - Threshold
Adjustable/Selectable
Operating Temperature
-40°C ~ 85°C
Mounting Type
Surface Mount
Package / Case
24-TQFN Exposed Pad
Monitored Voltage
- 0.3 V to + 6 V
Manual Reset
Not Resettable
Watchdog
No Watchdog
Supply Voltage (max)
5.5 V
Supply Voltage (min)
2.7 V
Supply Current (typ)
1100 uA
Maximum Power Dissipation
1667 mW
Maximum Operating Temperature
+ 85 C
Mounting Style
SMD/SMT
Minimum Operating Temperature
- 40 C
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
MAX6877
10
11
12
13
1
2
3
4
5
6
7
8
9
MAX6878
3, 16, 17,
PIN
22
10
11
12
13
1
2
4
5
6
7
8
9
______________________________________________________________________________________
MAX6879
1
2
3
4
5
6
7
8
9
Dual-/Triple-Voltage, Power-Supply
Trackers/Sequencers/Supervisors
LTCH/RTR
TIMEOUT
TRK/SEQ
MARGIN
DELAY
NAME
EN/UV
SLEW
SET3
SET2
SET1
GND
N.C.
V
ABP
CC
Optional Supply Voltage Input. Connect V
supply if desired. Leave V
supplies less than UVLO to be tracked. V
100kΩ resistor.
Internal Supply Bypass Input. Bypass ABP with a 1µF capacitor to GND. ABP
maintains the device supply voltage during rapid power-down conditions.
Externally Adjusted IN_ Undervoltage Lockout Threshold. Connect SET_ to
an external resistor-divider network to set the desired undervoltage threshold
for each IN_ supply (see the Typical Application Circuit). All SET_ inputs
must be above the internal SET_ threshold (0.5V) to enable tracking or
sequencing functionality.
No Connection. Not internally connected.
Logic-Enable Input or Undervoltage Lockout Monitor Input. EN/UV must be
high (EN/UV > V
operation. OUT_ begins tracking down when EN/UV < V
to an external resistor-divider network to set the external UVLO threshold.
Ground
Tracking Startup/Sequence Delay Select Input. Connect a capacitor from
DELAY to GND to select the desired delay period before tracking is enabled
(after all SET_ inputs and EN/UV are above their respective thresholds) or
between supply sequences. Leave DELAY unconnected for the default
200µs delay period.
Slew-Rate Adjustment Input. Connect a capacitor from SLEW to GND to
select the desired OUT_ slew rate.
PG/RST Timeout Period Adjust Input. PG/RST asserts high after the timeout
period when all OUT_ exceed their IN_ referenced threshold. Connect a
capacitor from TIMEOUT to GND to set the desired timeout period. Leave
TIMEOUT unconnected for the default 200µs delay period.
Latch/Autor etr y S el ecti on Inp ut. D r i ve L TC H/RTR l ow to sel ect the l atch m od e.
C onnect L TC H/RTR to ABP or l eave unconnected to sel ect autor etr y m od e.
L TC H/RTR i s i nter nal l y p ul l ed up to ABP thr oug h a 10µA cur r ent sour ce.
Track/Sequence Select Input. Drive TRK/SEQ low to enable supply tracking
function. Connect TRK/SEQ to ABP or leave it unconnected to enable supply
sequencing. TRK/SEQ is internally pulled to ABP through a 10µA current
source.
Margin Input, Active-Low. Drive MARGIN low to enable margin mode (see
the Margin Input ( MARGIN ) section). The MARGIN functionality is disabled
(returns to normal monitoring mode) after MARGIN returns high. MARGIN is
internally pulled up to ABP through a 10µA current source.
EN_R
) to enable voltage tracking or sequencing power-up
CC
unconnected, if not used. V
FUNCTION
CC
CC
is internally pulled down by a
to an alternate (i.e., always-on)
Pin Description
EN_F
CC
allows IN_
. Connect EN/UV
13

Related parts for MAX6877ETG+