MAX16004ATP+ Maxim Integrated Products, MAX16004ATP+ Datasheet - Page 8

IC UP SUPERVISOR HEX 20-TQFN

MAX16004ATP+

Manufacturer Part Number
MAX16004ATP+
Description
IC UP SUPERVISOR HEX 20-TQFN
Manufacturer
Maxim Integrated Products
Type
Multi-Voltage Supervisorr
Datasheet

Specifications of MAX16004ATP+

Number Of Voltages Monitored
6
Output
Open Drain or Open Collector
Reset
Active Low
Reset Timeout
Adjustable/Selectable
Voltage - Threshold
6 Selectable Threshold Combinations
Operating Temperature
-40°C ~ 125°C
Mounting Type
Surface Mount
Package / Case
20-TQFN Exposed Pad
Monitored Voltage
1.8 V, 2.5 V, 3.3 V, Adjustable
Undervoltage Threshold
2.97 V, 2.25 V, 1.62 V, Adjustable
Overvoltage Threshold
1.71 V, 2.375 V, 3.135 V, Adjustable
Output Type
Active Low, Open Drain
Manual Reset
Resettable
Watchdog
Watchdog
Battery Backup Switching
No Backup
Power-up Reset Delay (typ)
280 ms
Supply Voltage (max)
5.5 V
Supply Voltage (min)
1 V
Supply Current (typ)
50 uA
Maximum Power Dissipation
1355 mW
Maximum Operating Temperature
+ 125 C
Mounting Style
SMD/SMT
Minimum Operating Temperature
- 40 C
Power Fail Detection
No
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Low-Voltage, Quad-/Hex-/Octal-Voltage
µP Supervisors
8
10
11
12
13
14
15
1
2
3
4
5
6
7
8
9
_______________________________________________________________________________________
PIN
12
13
14
15
17
18
19
1
2
3
5
6
7
8
9
13
15
16
3
4
5
7
8
1
11
13
14
15
1
2
3
5
6
MARGIN
NAME
OUT4
OUT5
OUT6
OUT3
OUT2
OUT1
GND
V
IN4
IN5
IN6
IN1
IN2
IN3
CC
Monitored Input Voltage 4. See Table 1 for the input voltage threshold.
Monitored Input Voltage 5. See Table 1 for the input voltage threshold.
Monitored Input Voltage 6. See Table 1 for the input voltage threshold.
Ground
Unmonitored Power-Supply Input
Output 4. When the voltage at IN4 falls below its threshold, OUT4 goes low and stays low
until the voltage at IN4 exceeds its threshold. The open-drain output has a 30µA internal
pullup to V
Output 5. When the voltage at IN5 falls below its threshold, OUT5 goes low and stays low
until the voltage at IN5 exceeds its threshold. The open-drain output has a 30µA internal
pullup to V
Output 6. When the voltage at IN6 falls below its threshold, OUT6 goes low and stays low
until the voltage at IN6 exceeds its threshold. The open-drain output has a 30µA internal
pullup to V
Manual Deassert Input. Pull MARGIN low to deassert all outputs (go into high state),
regardless of the voltage at any monitored input.
Output 3. When the voltage at IN3 falls below its threshold, OUT3 goes low and stays low
until the voltage at IN3 exceeds its threshold. The open-drain output has a 30µA internal
pullup to V
Output 2. When the voltage at IN2 falls below its threshold, OUT2 goes low and stays low
until the voltage at IN2 exceeds its threshold. The open-drain output has a 30µA internal
pullup to V
Output 1. When the voltage at IN1 falls below its threshold, OUT1 goes low and stays low
until the voltage at IN1 exceeds its threshold. The open-drain output has a 30µA internal
pullup to V
Monitored Input Voltage 1. See Table 1 for the input voltage threshold.
Monitored Input Voltage 2. See Table 1 for the input voltage threshold.
Monitored Input Voltage 3. See Table 1 for the input voltage threshold.
Pin Description (MAX16003/MAX16004/MAX16005)
CC
CC
CC
CC
CC
CC
.
.
.
.
.
.
FUNCTION

Related parts for MAX16004ATP+