78M6612-DB/OMU-USB Maxim Integrated Products, 78M6612-DB/OMU-USB Datasheet - Page 31

KIT DEMO OUTLET MEASUREMENT OMU1

78M6612-DB/OMU-USB

Manufacturer Part Number
78M6612-DB/OMU-USB
Description
KIT DEMO OUTLET MEASUREMENT OMU1
Manufacturer
Maxim Integrated Products

Specifications of 78M6612-DB/OMU-USB

Data Bus Width
8 bit
Interface Type
USB
Tool Type
Demonstration Board
Core Architecture
8051
Cpu Core
80515
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
UG_6612_ 017
Rev. 1.0
Factor_nb B
Factor_nb B
VARs_nb B
VARs_nb B
Angle_nb B
Angle_nb B
Irms_nb B
Irms_nb B
VAs_nb B
VAs_nb B
Reserved
Reserved
Output
Power
Power
Phase
Phase
Max
Max
Max
Max
Max
Min
Min
Min
Min
Min
Location
(hex)
5A
5B
5C
5D
5E
54
55
56
57
58
59
5F
mArms
mArms
LSB
mW
mW
mW
mW
Outlet 2 maximum narrowband rms
power factor measured. Maximum
Outlet 2 minimum narrowband rms
power factor measured. Minimum
is defined as the most negative or
is defined as the most positive or
Outlet 2 maximum narrowband
apparent power measured (per
Outlet 2 maximum narrowband
apparent power measured (per
Outlet 2 maximum narrowband
Outlet 2 maximum narrowband
Outlet 2 minimum narrowband
Outlet 2 minimum narrowband
Outlet 2 minimum narrowband
Outlet 2 minimum narrowband
reactive power measured (per
reactive power measured (per
6612_OMU_S2+2_URT_V1_14 Firmware Description Document
phase angle measured.
phase angle measured.
least negative number.
least positive number.
current measured.
current measured.
Comment
Reserved
Reserved
second).
second).
second).
second)
If the maximum narrowband phase
If the minimum narrowband phase
If the smallest narrowband current
factor measured on Outlet 2 is 0.9
measured on Outlet 2 is 30 Amps
measured on Outlet 2 is 80 VARs
If the largest narrowband current
angle measured on Outlet 2 is 10
angle measured on Outlet 2 is 70
If the largest VARs measured on
If the largest narrowband VARs
measured on Outlet 2 is 1 Amp
If the smallest narrowband VAs
If maximum narrowband power
If minimum narrowband power
factor measured on Outlet 2 is
If the largest narrowband VAs
measured on Outlet 2 is
measured on Outlet 2 is
)5A?<CR> Returns:
)5B?<CR> Returns:
Outlet 2 is 80 VARs
)5C?<CR>
)5D?<CR>
Example
)54?<CR>
)55?<CR>
)56?<CR>
300 VARs
)57?<CR>
)58?<CR>
300 VARs
)59?<CR>
Reserved
Reserved
+300.000
+300.000
Returns:
Returns:
Returns:
Returns:
Returns:
Returns:
Returns:
Returns:
+30.000
+80.000
+80.000
degrees
+10.000
degrees
+70.000
+1.000
+0.900
-0.600
-0.6
31