XBIB-U Digi International/Maxstream, XBIB-U Datasheet - Page 28

no-image

XBIB-U

Manufacturer Part Number
XBIB-U
Description
BOARD USB ZIGBEE MOD PRO
Manufacturer
Digi International/Maxstream
Datasheets

Specifications of XBIB-U

Design Resources
XBIB-U Shematic
Accessory Type
Interface Board
For Use With/related Products
XBee and XBee Pro Radios
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
XBIB-U-DEV
Manufacturer:
DIGI
Quantity:
20 000
Table 3‐02. XBee/XBee‐PRO Commands ‐ Networking & Security (Sub‐categories designated within {brackets})
XBee/XBee‐PRO™ OEM RF Modules ‐ 802.15.4 ‐ v1.xAx [2007.05.031]
AT
Command
A2 ( v1.x80*)
AI ( v1.x80*)
DA ( v1.x80*)
FP ( v1.x80*)
Command
Category
Networking
{Association}
Networking
{Association}
Networking
{Association}
Networking
{Association}
Name and Description
Coordinator Association. Set/Read Coordinator association options.
bit 0 - ReassignPanID
bit 1 - ReassignChannel -
bit 2 - AllowAssociation -
bits 3 - 7 are reserved
Association Indication. Read errors with the last association request:
0x00 - Successful Completion - Coordinator successfully started or End Device
0x01 - Active Scan Timeout
0x02 - Active Scan found no PANs
0x03 - Active Scan found PAN, but the CoordinatorAllowAssociation bit is not set
0x04 - Active Scan found PAN, but Coordinator and End Device are not
0x05 - Active Scan found PAN, but the Coordinator ID parameter does not match
0x06 - Active Scan found PAN, but the Coordinator CH parameter does not match the
0x07 - Energy Scan Timeout
0x08 - Coordinator start request failed
0x09 - Coordinator could not start due to invalid parameter
0x0A - Coordinator Realignment is in progress
0x0B - Association Request not sent
0x0C - Association Request timed out - no reply was received
0x0D - Association Request had an Invalid Parameter
0x0E - Association Request Channel Access Failure. Request was not transmitted -
0x0F - Remote Coordinator did not send an ACK after Association Request was sent
0x10 - Remote Coordinator did not reply to the Association Request, but an ACK was
0x11 - [reserved]
0x12 - Sync-Loss - Lost synchronization with a Beaconing Coordinator
0x13 - Disassociated - No longer associated to Coordinator
Force Disassociation. End Device will immediately disassociate from a Coordinator (if
associated) and reattempt to associate.
Force Poll. Request indirect messages being held by a coordinator.
© 2007 MaxStream, Inc.
0 - Coordinator will not perform Active Scan to locate available PAN ID. It will operate
1 - Coordinator will perform Active Scan to determine an available ID (PAN ID). If a
0 - Coordinator will not perform Energy Scan to determine free channel. It will operate
1 - Coordinator will perform Energy Scan to find a free channel, then operate on that
0 - Coordinator will not allow any devices to associate to it.
1 - Coordinator will allow devices to associate to it.
on ID (PAN ID).
PAN ID conflict is found, the ID parameter will change.
on the channel determined by the CH parameter.
channel.
CH parameter of the End Device
received after sending the request
association complete
the ID parameter of the End Device
CCA failure
configured to support beacons
Chapter 3 ‐ RF Module Configuration
Parameter Range
0 - 7 [bitfield]
0 - 0x13 [read-only]
-
-