XBIB-U Digi International/Maxstream, XBIB-U Datasheet - Page 40

no-image

XBIB-U

Manufacturer Part Number
XBIB-U
Description
BOARD USB ZIGBEE MOD PRO
Manufacturer
Digi International/Maxstream
Datasheets

Specifications of XBIB-U

Design Resources
XBIB-U Shematic
Accessory Type
Interface Board
For Use With/related Products
XBee and XBee Pro Radios
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
XBIB-U-DEV
Manufacturer:
DIGI
Quantity:
20 000
XBee/XBee‐PRO™ OEM RF Modules ‐ 802.15.4 ‐ v1.xAx [2007.05.031]
D7 (DIO7 Configuration) Command
D8 (DI8 Configuration) Command
DA (Force Disassociation) Command
DB (Received Signal Strength) Command
DH (Destination Address High) Command
<I/O Settings> The D7 command is used to
select/read the behavior of the DIO7 line (pin 12).
Options include:
<I/O Settings> The D8 command is used to
select/read the behavior of the DI8 line (pin 9).
This command enables configuring the pin to
function as a digital input. This line is also used
with Pin Sleep.
<(Special)> The DA command is used to immedi-
ately disassociate an End Device from a Coordi-
nator and reattempt to associate.
<Diagnostics> DB parameter is used to read the
received signal strength (in dBm) of the last RF
packet received. Reported values are accurate
between -40 dBm and the RF module's receiver
sensitivity.
Absolute values are reported. For example: 0x58 = -88 dBm (decimal). If no packets have been
received (since last reset, power cycle or sleep event), “0” will be reported.
<Networking {Addressing}> The DH command is
used to set and read the upper 32 bits of the RF
module's 64-bit destination address. When com-
bined with the DL (Destination Address Low)
parameter, it defines the destination address used
for transmission.
An module will only communicate with other
modules having the same channel (CH parame-
ter), PAN ID (ID parameter) and destination address
(DH + DL parameters).
To transmit using a 16-bit address, set the DH parameter to zero and the DL parameter less than
0xFFFF. 0x000000000000FFFF (DL concatenated to DH) is the broadcast address for the PAN.
Refer to the XBee/XBee-PRO Addressing section for more information.
© 2007 MaxStream, Inc.
• CTS flow control
• Analog-to-digital converter
• Digital input
• Digital output
AT Command: ATDA
Minimum Firmware Version Required: v1.x80
AT Command: ATDH
Parameter Range: 0 - 0xFFFFFFFF
Default Parameter Value: 0
Related Commands: DL (Destination Address
Low), CH (Channel), ID (PAN VID), MY (Source
Address)
AT Command: ATDB
Parameter Range [read-only]:
0x17-0x5C (XBee), 0x24-0x64 (XBee-PRO)
AT Command: ATD7
Parameter Range:0 - 5
Default Parameter Value:1
Parameters 3-5 supported as of firmware
version 1.x.A0
AT Command: ATD8
Parameter Range:0 - 5
Default Parameter Value:0
Minimum Firmware Version Required: 1.xA0
Parameter
Parameter
Chapter 3 ‐ RF Module Configuration
0
1
2
3
4
5
0
3
(1, 2, 4 & 5 n/a)
CTS Flow Control
Configuration
Configuration
Disabled
Disabled
DO high
DO low
n/a
DI
DI
     40

Related parts for XBIB-U