STEVAL-SPBT2ATV1 STMicroelectronics, STEVAL-SPBT2ATV1 Datasheet - Page 39

BOARD DEMO BLUETOOTH SPBT2532C2

STEVAL-SPBT2ATV1

Manufacturer Part Number
STEVAL-SPBT2ATV1
Description
BOARD DEMO BLUETOOTH SPBT2532C2
Manufacturer
STMicroelectronics
Type
Bluetooth 2.0r
Datasheets

Specifications of STEVAL-SPBT2ATV1

Frequency
2.4GHz
Product
RF Modules
Supply Voltage (max)
6 V
Maximum Operating Temperature
+ 85 C
Supply Voltage (min)
4 V
For Use With/related Products
SPBT2532C2
Lead Free Status / RoHS Status
Lead free by exemption / RoHS compliant by exemption
Other names
497-10656
SPBT2532C2.AT
D.29
D.29.1
D.29.2
D.29.3
D.30
D.30.1
D.30.2
StreamingSerial
The StreamingSerial command is used to enable/disable the UART flow control.
Syntax
AT+AB StreamingSerial [Enable/Disable]
Where [Enable/Disable] is an e or E character to enable this parameter and a d or D
character to disable it. StreamingSerial command will disable RTS/CTS hardware flow
control and discard non-transmitted data when enabled. RTS/CTS flow control is enabled,
when StreamingSerial is disabled.
Query
An alternative syntax may be used to query the current StreamingSerial feature status. This
syntax is not supported by other commands.
AT+AB StreamingSerial
Responses
If the feature is successfully applied or queried, the response is:
AT-AB StreamingSerial [Enabled/Disabled]
UpdateInquiryScan
The UpdateInquiryScan command is used to modify the Inquiry scan parameters: mode,
duration, and interval.
Syntax
AT+AB UpdateInquiryScan [mode] [duration] [interval]
where[mode] is the discoverable mode:
[duration] is the scan length in slots; 18 to 4096. The default duration is 18 slots.
[interval] is the period between scans in slots; 18 to 4096. The default interval is 2048
slots
Responses
If the command is successful, the response is:
AT-AB InquiryScanUpdateDone
0: non-discoverable
1: limited discoverability – not supported
2: discoverable