XB24-BPDK Digi International/Maxstream, XB24-BPDK Datasheet - Page 61

no-image

XB24-BPDK

Manufacturer Part Number
XB24-BPDK
Description
KIT DEVELOPMENT XBEE SERIES 2
Manufacturer
Digi International/Maxstream
Series
XBee™r
Type
802.15.4/Zigbeer
Datasheet

Specifications of XB24-BPDK

Frequency
2.4GHz
For Use With/related Products
XBee™ Series 2 Modules
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
XBee ZNet 2.5/XBee‐PRO ZNet 2.5 ZigBee OEM RF Modules v1.x4x 
Identifies the UART data frame for the host to
correlate with a subsequent ACK (acknowledgement).
If set to ‘0’, no AT Command Response will be given.
Frame ID (Byte 5)
Start Delimiter
0x7E
64-bit Destination Address
Identifies the UART data frame being reported.
Note: If Frame ID = 0 in AT Command Mode,
no AT Command Response will be given.
Set to match the 64-bit address
of the destination, MSB first,
LSB last. Broadcast =
0x000000000000FFFF.
(bytes 6-13)
MSB
AT Command Response
Remote AT Command Request
Length
Start Delimiter
API Identifier Value: 0x88
Response to previous command.
In response to an AT Command message, the module will send an AT Command Response
message. Some commands will send back multiple frames (for example, the ND (Node Discover)
command).
Figure 6‐9.
API Identifier Value: 0x17
Allows for module parameter registers on a remote device to be queried or set
Figure 6‐10. Remote AT Command Request
0x7E
LSB
Frame ID (Byte 5 )
© 2008 Digi International, Inc.
API Identifier
0x17
API-specific Structure
MSB
Frame Data
AT Command Response Frames.
Length
Identifier-specific Data
LSB
API Identifier
cmdData
0x88
API-specific Structure
Set to match the 16-bit network
address of the destination, MSB
first, LSB last. Set to 0xFFFE for
broadcast TX, or if the network
address is unknown.
Command Name - Two
ASCII characters that
identify the AT Command.
Frame Data
AT Command (Bytes 6-7)
Checksum
1 Byte
16-bit Destination Network Address
Identifier-specific Data
cmdData
Command Options (byte 16)
(bytes 14-15)
Checksum
1 Byte
0x02 - Apply changes on remote. (If
not set, AC command must be sent
before changes will take effect.)
All other bits must be set to 0.
Status (Byte 8)
0 = OK
1 = ERROR
2 = Invalid Command
3 = Invalid Parameter
Command Name (bytes
Name of the
command
17-18)
The HEX (non-ASCII) value
of the requested register
Value (Byte(s) 9-n)
If present, indicates the requested
parameter value to set the given
register. If no characters present,
the register is queried.
Command Data (byte 19-n)
     60

Related parts for XB24-BPDK