XT09-SI-MESH Digi International, XT09-SI-MESH Datasheet - Page 29

no-image

XT09-SI-MESH

Manufacturer Part Number
XT09-SI-MESH
Description
MODULE RF 900MHZ 1W 115K W/RPSMA
Manufacturer
Digi International
Datasheets

Specifications of XT09-SI-MESH

Frequency
900MHz
Modulation Or Protocol
FHSS, FSK
Power - Output
1W
Sensitivity
-100dBm
Voltage - Supply
2.8 V ~ 5.5 V
Current - Receiving
80mA
Antenna Connector
RP-SMA
Operating Temperature
-40°C ~ 85°C
Package / Case
Module
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Applications
-
Memory Size
-
Data Interface
-
Data Rate - Maximum
-
Current - Transmitting
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
602-1183
XTend™ RF Module ‐ Product Manual v2.x6x
LH (Wake-up Initializer Timer) Command
MD (RF Mode) Command
MK (Address Mask) Command
from a module without a key, but the output will be meaningless. Because CBC mode is utilized,
repetitive data appears differently in different transmissions due to the randomly-generated IV.
NOTE: For international (non-U.S.) variants of XTend modules, the encryption key is 128-bit AES.
The command operates the same except the key length is 16 bytes rather than 32 bytes. This per-
tains to part numbers ending with -NA or -128 (the -NA and -128 suffix mean the same thing), no
matter what firmware version is loaded. This also pertains to the Australia version of firmware
22xx, no matter what part number XTend it is loaded onto.
<Sleep (Low Power)> The LH Command is used
to set/read the duration of time during which the
wake-up initializer is sent. When receiving mod-
ules are in Cyclic Sleep Mode, they power-down
after a period of inactivity (as specified by the ST
parameter) and will periodically wake and listen
for transmitted data. In order for the receiving
modules to remain awake, they must detect
~35ms of the wake-up initializer.
LH Command must be used whenever a receiving
module is operating in Cyclic Sleep Mode. The
Wake-up Initializer Time must be longer than the cyclic sleep time that [as determined by SM
(Sleep Mode) parameter]. If the wake-up initializer time were less than the Cyclic Sleep interval,
the connection would be at risk of missing the wake-up initializer transmission.
Refer to figures loated under the SM command description to view diagrams of correct and incor-
rect configurations. The images emphasize that the LH value must be greater than the SM value.
<Networking & Security> The MD command is
used to select/read the settings that enable the
Polling and Repeater Modes on the module.
Polling Mode - A ‘Polling Base’ is responsible for
polling remotes. A ‘Polling Remote’ requires a poll
in order to transmit.
Repeater Mode - A ‘Repeater’ re-sends RF data
unless the transmission is addressed to it or if the
transmission has already been detected. A
‘Repeater End Node’ handles repeated messages,
but will not repeat the message over-the-air.
Refer to the Polling and Repeater Mode sections of
the ‘RF Communication Modes’ chapter for more
information.
<Networking & Security> The MK command is
used to set/read the Address Mask of a module.
All RF data packets contain the Destination
Address of the TX (transmitting) module. When a
packet is received, the TX module Destination
Address is logically "ANDed" (bitwise) with the
Address Mask of the RX (receiving) module. The
resulting value must match the Destination
Address or Address Mask of the RX module for the
© 2010 Digi Internatonal, Inc.
AT Command: ATLH
Binary Command: 0x0C (12 decimal)
Parameter Range:0 - 0xFF
Default Parameter Value: 1
Number of bytes returned: 1
Related Commands: HT (Time before Wake-up
Initializer), SM (Sleep Mode), ST (Time before
Sleep)
AT Command: ATMD
Binary Command: 0x31 (49 decimal)
Parameter Range: 0 - 6
Default Parameter Value: 0
Number of bytes returned: 1
Minimum Firmware Version Required: 2.x20
AT Command: ATMK
Binary Command: 0x12 (18 decimal)
Parameter Range:0 - 0xFFFF
Default Parameter Value: 0xFFFF (65535d)
Number of bytes returned: 2
Related Commands: DT (Destination Address),
HP (Hopping Channel), ID (Modem VID), MY
(Source Address)
Parameter
0
1
2
3
4
5
6
[x 100 milliseconds]
Transparent Operation
[reserved - not used]
[reserved - not used]
Repeater End Node
(Repeater Base)
Polling Remote
Configuration
Polling Base
Repeater
     29

Related parts for XT09-SI-MESH