Specifications of XBP09-DPUIT-156

Frequency
902MHz ~ 928MHz
Data Rate - Maximum
156kbps
Modulation Or Protocol
FHSS
Applications
ISM
Power - Output
17dBm (50mW)
Sensitivity
-100dBm
Voltage - Supply
3 V ~ 3.6 V
Current - Receiving
80mA
Current - Transmitting
210mA
Data Interface
PCB, Through Hole
Antenna Connector
U.FL
Operating Temperature
-40°C ~ 85°C
Package / Case
Module
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Memory Size
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
602-1168
Diagnostics
Diagnostics Commands
XBee‐PRO® 900 RF Modules  
AT
Command
VR
HV
CK
ER
GD
RP
TR
TP
DB
%V
Name and Description
Firmware Version. Read firmware version of the module.
Hardware Version. Read hardware version of the module.
Configuration Code. Read the configuration code associated with the current AT
command configuration.The code returned can be used as a quick check to determine if
a node has been configured as desired.
RF Errors. Read the number of times a packet was received which contained integrity
errors of some sort. When the value reaches 0xFFFF, it stays there.
Good packets. Read the number of good frames with valid MAC headers that are
received on the RF interface. When the value reaches 0xFFFF, it stays there.
RSSI PWM timer. Set or read the time that the RSSI output (indicating signal strength)
will remain active after the last reception. Time units are measured in tenths of seconds
Transmission Errors. Read the number of MAC frames that exhaust MAC retries
without ever receiving a MAC acknowledgement message from the adjacent node.
When the value reaches 0xffff, it stays there.
Temperature. Read module temperature in Celsius. Negatives temperatures can be
returned.
Received Signal Strength.
This command reports the received signal strength of the last received RF data packet.
The DB command only indicates the signal strength of the last hop. It does not provide
an accurate quality measurement for a multihop link. The DB command value is
measured in -dBm. For example if DB returns 0x60, then the RSSI of the last packet
received was -96dBm.
An XBee-PRO 900 module will only report RSSI values within approximately 15 dBm of
the sensitivity level of the module. Signals which exceed approximately -85dBm will be
reported as approximately -85dBm.
Supply Voltage. Reads the voltage on the Vcc pin in mV. Read module voltage in
millivolts.
© 2009 Digi International, Inc.
Parameter Range
0 - 0xFFFFFFFF [read-
only]
0 - 0xFFFF [read-only]
0-0xFFFFFFFF
n/a
n/a
1 to 0xff
n/a
0xff74 to 0x0258
n/a
0-0x/F00
Default
Firmware-set
Factory-set
n/a
n/a
n/a
0x20 = 3.2
seconds
n/a
n/a
n/a
n/a