DSEP2X31-06B IXYS, DSEP2X31-06B Datasheet

no-image

DSEP2X31-06B

Manufacturer Part Number
DSEP2X31-06B
Description
DIODE FRED 600V 30A SOT-227B
Manufacturer
IXYS
Series
HiPerFRED™r
Datasheet

Specifications of DSEP2X31-06B

Voltage - Forward (vf) (max) @ If
2.49V @ 30A
Current - Reverse Leakage @ Vr
250µA @ 600V
Current - Average Rectified (io) (per Diode)
30A
Voltage - Dc Reverse (vr) (max)
600V
Reverse Recovery Time (trr)
30ns
Diode Type
Standard
Speed
Fast Recovery =< 500ns, > 200mA (Io)
Diode Configuration
2 Independent
Mounting Type
Chassis Mount
Package / Case
SOT-227, miniBLOC
Vrrm, (v)
600
Ifavm, D = 0.5, Total, (a)
60
Ifavm, D = 0.5, Per Diode, (a)
30
@ Tc, (°c)
75
Ifrms, (a)
100
Ifsm, 10 Ms, Tvj=45°c, (a)
250
Vf, Max, Tvj =150°c, (v)
1.59
@ If, (a)
30
Trr, Typ, Tvj =25°c, (ns)
20
Irm , Typ, Tvj =100°c, (a)
12.5
@ -di/dt, (a/µs)
400
Tvjm, (°c)
150
Rthjc, Max, (k/w)
1.15
Package Style
SOT-227B
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
DSEP2X31-06B
Manufacturer:
IXYS
Quantity:
26
Part Number:
DSEP2X31-06B
Manufacturer:
IXYS
Quantity:
6 285
Part Number:
DSEP2X31-06B
Manufacturer:
IXYS/艾赛斯
Quantity:
20 000
Part Number:
DSEP2X31-06B
Quantity:
250
HiPerFRED
with soft recovery
V
Symbol
I
I
I
E
I
T
T
T
P
V
M
Weight
Symbol
I
V
R
R
t
I
Pulse test:
Data according to IEC 60747 and per diode unless otherwise specified
IXYS reserves the right to change limits, test conditions and dimensions.
© 2000 IXYS All rights reserved
600
600
FRMS
FAVM
FSM
AR
R
RM
rr
V
VJ
VJM
stg
tot
ISOL
F
RSM
AS
thJC
thCH
d
V
600
600
Pulse Width = 5 ms, Duty Cycle < 2.0 %
Pulse Width = 300 ms, Duty Cycle < 2.0 %
RRM
V
Conditions
rect., d = 0.5; T
T
T
I
V
T
50/60 Hz, RMS
I
mounting torque (M4)
terminal connection torque (M4)
typical
Conditions
T
T
I
I
V
V
T
AS
ISOL
F
F
VJ
VJ
C
VJ
VJ
VJ
A
R
R
= 30 A;
= 1 A; -di/dt = 200 A/ms;
= 1 A; L = 180 µH
= 1.5·V
= 25°C
= 30 V; T
= 100 V; I
= 45°C; t
= 25°C; non-repetitive
= 25°C V
= 150°C V
= 100°C
£ 1 mA
Type
DSEP 2x 31-06A
DSEP 2x 31-06B
TM
R
typ.; f = 10 kHz; repetitive
p
VJ
T
T
F
= 10 ms (50 Hz), sine
T
VJ
VJ
R
R
= 25°C
= 50 A; -di
C
C
Epitaxial Diode
= V
= V
= 125°C
= 25°C
(Vers. A) = 95°C
(Vers. B) = 85°C
RRM
RRM
F
/dt = 100 A/ms
Characteristic max. Values
typ. 0.1
Vers. A
typ. 35
typ. 6
1.1-1.5/9-13
1.1-1.5/9-13
0.25
1.30
1.58
1.15
-40...+150
-40...+150
1
Maximum Ratings
2500
Vers. B
typ. 0.1
250
150
100
typ. 30
0.2
0.1
30
30
70
typ. 4
0.25
1.73
2.49
1.15
2
Nm/lb.in.
Nm/lb.in.
K/W
K/W
mA
mA
mJ
V~
°C
°C
°C
ns
W
A
A
A
A
V
V
A
g
I
V
t
miniBLOC, SOT-227 B
Features
Applications
Advantages
Dimensions see outlines.pdf
FAV
rr
International standard package
miniBLOC
Isolation voltage 2500 V~
UL registered E 72873
2 independent FRED in 1 package
Planar passivated chips
Very short recovery time
Extremely low switching losses
Low I
Soft recovery behaviour
Antiparallel diode for high frequency
switching devices
Antisaturation diode
Snubber diode
Free wheeling diode in converters
and motor control circuits
Rectifiers in switch mode power
supplies (SMPS)
Inductive heating
Uninterruptible power supplies (UPS)
Ultrasonic cleaners and welders
Avalanche voltage rated for reliable
operation
Soft reverse recovery for low
EMI/RFI
Low I
- Power dissipation within the diode
- Turn-on loss in the commutating
RRM
switch
RM
RM
= 2x 30 A
= 600 V
= 30/35 ns
-values
reduces:
DSEP 2x 31-06A
DSEP 2x 31-06B
1 - 3

Related parts for DSEP2X31-06B

DSEP2X31-06B Summary of contents

Page 1

... Pulse test: Pulse Width = 5 ms, Duty Cycle < 2.0 % Pulse Width = 300 ms, Duty Cycle < 2.0 % Data according to IEC 60747 and per diode unless otherwise specified IXYS reserves the right to change limits, test conditions and dimensions. © 2000 IXYS All rights reserved Maximum Ratings 70 ...

Page 2

... T VJ Fig. 4 Dynamic parameters versus K thJC 0.1 0.01 0.001 0.0001 0.001 Fig. 7 Transient thermal resistance junction to case NOTE: Fig Fig. 6 shows typical values © 2000 IXYS All rights reserved 3000 T = 100° 300V R 2500 Q r 2000 I = 60A 30A F 1500 I = 15A ...

Page 3

... T VJ Fig. 4 Dynamic parameters versus K thJC 0.1 0.01 0.001 0.0001 0.00001 0.0001 0.001 Fig. 7 Transient thermal resistance junction to case NOTE: Fig Fig. 6 shows typical values © 2000 IXYS All rights reserved 1000 T = 100° 300V R 800 I = 60A 30A 15A F 600 400 ...

Related keywords