SWITCH PB MUSH MOM SPST-NO/C WHT

A22-SW-11M

Manufacturer Part Number
A22-SW-11M
Description
SWITCH PB MUSH MOM SPST-NO/C WHT
Manufacturer
Omron
Series
A22r
Type
Standardr
Datasheets

Specifications of A22-SW-11M

Circuit
DPST (1-NO, 1-NC)
Switch Function
On-Mom, Off-Mom
Contact Rating @ Voltage
10A @ 110VAC
Actuator Type
Mushroom Button
Mounting Type
Panel Mount
Termination Style
Screw Terminal
Contact Form
SPST - NC-NO
Contact Rating
10 mAmps
Actuator
Round, Mushroom
Mounting Style
Panel
Illumination
Illuminated
Illumination Color
White
Body Shape
Square
Dielectric Strength
2500 Volts
Insulation Resistance
100 MOhms
Mounting Angle
Straight
Operating Force
29.4 N
Water / Moisture Rating
IP65
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Illumination Type, Color
-
Illumination Voltage (nominal)
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
A22SW11M
Square Pushbutton/Indicator
Emergency Stop Switch
Square Pushbutton/Indicator
Insert the protruding tip of the Cap Puller (A3PJ-5080) into the Cap
slot, hold the plate spring, and pull them to remove the Color Cap.
Mounting the Color Cap:
Mount the Color Cap on the flange and firmly push the Color Cap.
When the Color Cap is inserted, check whether it operates properly.
When replacing the Lamp, remove the Color Cap and diffusion
plate with fingers or Cap Puller.
Attach the Character Film properly so that it fits inside the
protruding part of the diffusion plate. Then, match the diffusion plate
to the square flange and insert the Cap.
Insert the protrusion of the Tightening Wrench (A22Z-3905) into the
Cap slot and then turn to remove the Cap.
http://www.ia.omron.com/
Plate spring
Diffusion plate
Character Film
Flange
Color Cap
Installing/Replacing the Lamp
Installing/Replacing from the Panel Surface
Installing/Replacing on the Switch
Control Box (Enclosure)
Mounting the Switch
The Standard-size Legend Plate Frame can be mounted. Mount the
Frame as shown in the following diagram. Mount the Switch in the
same way as for an ordinary panel.
Creating a Cable Port Hole
Place the tip of a screwdriver on the surface where the cable port hole
is to be created with the cover attached and strike the screwdriver with
a hammer to punch four holes.
Insert the Lamp Extractor (A22Z-3901) into the lamp, then rotate
the Extractor while pressing it.
Grip the lamp with your fingers, then rotate the lamp while pressing
it against the Switch.
Groove
(c)Copyright OMRON Corporation 2007 All Rights Reserved.
Switch box
Screwdriver
Make four holes
in diagonal lines.
Snap-in Legend Plate
Side
Cover
Cable port hole
A22
26