S9S08DN32F1MLC Freescale Semiconductor, S9S08DN32F1MLC Datasheet - Page 307

IC MCU 8BIT 32KB FLASH 32LQFP

S9S08DN32F1MLC

Manufacturer Part Number
S9S08DN32F1MLC
Description
IC MCU 8BIT 32KB FLASH 32LQFP
Manufacturer
Freescale Semiconductor
Series
HCS08r
Datasheets

Specifications of S9S08DN32F1MLC

Core Processor
HCS08
Core Size
8-Bit
Speed
40MHz
Connectivity
I²C, LIN, SCI, SPI
Peripherals
LVD, POR, PWM, WDT
Number Of I /o
25
Program Memory Size
32KB (32K x 8)
Program Memory Type
FLASH
Eeprom Size
1K x 8
Ram Size
1.5K x 8
Voltage - Supply (vcc/vdd)
2.7 V ~ 5.5 V
Data Converters
A/D 10x12b
Oscillator Type
Internal
Operating Temperature
-40°C ~ 125°C
Package / Case
32-LQFP
Processor Series
S08D
Core
HCS08
Data Bus Width
8 bit
Data Ram Size
1 KB
Interface Type
I2C, SCI, SPI
Maximum Clock Frequency
40 MHz
Number Of Programmable I/os
26
Operating Supply Voltage
3 V to 5 V
Maximum Operating Temperature
+ 125 C
Mounting Style
SMD/SMT
3rd Party Development Tools
EWS08
Development Tools By Supplier
DEMO9S08DZ60
Minimum Operating Temperature
- 40 C
On-chip Adc
12 bit, 10 Channel
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
S9S08DN32F1MLC
Manufacturer:
Freescale Semiconductor
Quantity:
10 000
Part Number:
S9S08DN32F1MLC
Manufacturer:
FREESCALE
Quantity:
20 000
16.4.3.8
This register can be read any time, but may be written only if ARM = 0, except bits 4 and 5 are hard-wired
to 0s.
Freescale Semiconductor
Reset
TRG[3:0]
TRGSEL
BEGIN
Field
3:0
W
7
6
R
TRGSEL
Trigger Type — Controls whether the match outputs from comparators A and B are qualified with the opcode
tracking logic in the debug module. If TRGSEL is set, a match signal from comparator A or B must propagate
through the opcode tracking logic and a trigger event is only signalled to the FIFO logic if the opcode at the match
address is actually executed.
0 Trigger on access to compare address (force)
1 Trigger if opcode at compare address is executed (tag)
Begin/End Trigger Select — Controls whether the FIFO starts filling at a trigger or fills in a circular manner until
a trigger ends the capture of information. In event-only trigger modes, this bit is ignored and all debug runs are
assumed to be begin traces.
0 Data stored in FIFO until trigger (end trace)
1 Trigger initiates data storage (begin trace)
Select Trigger Mode — Selects one of nine triggering modes, as described below.
0000 A-only
0001 A OR B
0010 A Then B
0011 Event-only B (store data)
0100 A then event-only B (store data)
0101 A AND B data (full mode)
0110 A AND NOT B data (full mode)
0111 Inside range: A ≤ address ≤ B
1000 Outside range: address < A or address > B
1001 – 1111 (No trigger)
0
7
Debug Trigger Register (DBGT)
= Unimplemented or Reserved
BEGIN
0
6
Table 16-5. DBGT Register Field Descriptions
Figure 16-8. Debug Trigger Register (DBGT)
MC9S08DN60 Series Data Sheet, Rev 3
0
0
5
0
0
4
Description
TRG3
0
3
TRG2
0
2
Chapter 16 Development Support
TRG1
1
0
TRG0
0
0
307